Determination of Sensitivity and saturation limit of phosphor imaging plates for photon energies up to 1.25MeV

نویسنده

  • A. M. Shaikh
چکیده

Sensitivity calibration of imaging plates (IP) is important for quantitative measurements of intensity data obtained in various X-ray and gamma radiography experiments. To test the sensitivity of the IP (BAS2025) with the scanner (BAS5000) for higher photon energies, we have performed gamma exposure experimentsusing radionuclide (Co-57, Ba-133, Cs-137, Na-22 and Co-60). This provides useful information in assessing the intensities and dose received on IP in radiography especially with flash X-rays in the range 250keV to 1MeV.The IP was exposed for prolonged time to determine the saturation dose limit. The PSL intensity increases linearly up to 8x10 3 with dose received. With further increase in dose the intensity goes nonlinear till it gets saturated at ~9070 PSL. The observed photon sensitivity was measured as 1.383 x10 -4 PSL/photon for 114 keV, 1.101 x 10 -3 for 266 keV, 1.316 x 10 -3 for 662 keV, 4.111 x 10 -5 for 784 keV and 6.449 x 10 -5 for 1250 keV.Both the sensitivity and the saturation dose are dependent on the photon energy.The calibration data of the SR2025 IP is used in assessing the dose in flash radiography experiments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

A Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth

Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...

متن کامل

The effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT

Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans.   Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...

متن کامل

An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016