Compatible dual-echo arteriovenography (CODEA) using an echo-specific K-space reordering scheme.

نویسندگان

  • Sung-Hong Park
  • Chan-Hong Moon
  • Kyongtae Ty Bae
چکیده

An improved dual-echo sequence magnetic resonance (MR) imaging technique was developed to simultaneously acquire a time-of-flight MR angiogram (MRA) and a blood oxygenation level-dependent MR venogram (MRV) in a single MR acquisition at 3 T. MRA and MRV require conflicting scan conditions (e.g., excitation RF profile, flip angle, and spatial presaturation pulse) for their optimal image quality. This conflict was not well counterbalanced or reconciled in previous methods reported for simultaneous acquisition of MRA and MRV. In our dual-echo sequence method, an echo-specific K-space reordering scheme was used to uncouple the scan parameter requirements for MRA and MRV. The MRA and MRV vascular contrast was enhanced by maximally separating the K-space center regions acquired for the MRA and MRV, and by adjusting and applying scan parameters compatible between the MRA and MRV. As a preliminary result, we were able to acquire a simultaneous dual-echo MRA and MRV with image quality comparable to that of the conventional single-echo MRA and MRV that were acquired separately at two different sessions. Furthermore, integrated with tilted optimized nonsaturating excitation and multiple overlapping thin-slab acquisition techniques, our dual-echo MRA and MRV provided seamless vascular continuity over a large coverage volume of the brain anatomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective Application of Multiple Overlapping Thin-Slab Acquisition and Magnetization Transfer Contrast Pulse to Compatible Dual-Echo Arteriovenography (CODEA)

Introduction A newly introduced compatible dual-echo arteriovenography (CODEA) is a technique for simultaneous acquisition of time-of-flight (TOF) MR angiogram (MRA) and blood oxygenation level-dependent (BOLD) MR venogram (MRV). The technique improved the previous dual-echo MRA/MRV technique (1), by maximally separating the K-space center regions for the two echoes achieved through an echo-spe...

متن کامل

Three-Dimensional Segmentation and Visualization of Cerebral Arteries and Veins from Simultaneously Acquired MRA and MRV based on Graph-Cuts and Vessel Enhancement Filter

Introduction Accurate segmentation and appropriate visualization of the arteries and veins in the brain improve the detection and characterization of vascular abnormality such as cerebral aneurysm, arteriovenous malformation and tumor vascularity. Traditional 2D projection display of vascular images such as minimum-intensity projection (minIP) of veins in MRV offers limited visualization of com...

متن کامل

The shifted radial reordering for intermediate TE imaging in 3D long echo train acquisition

Introduction Use of nonselective pulses and modulated flip angles (aka SPACE, [2, 3, 4]) in refocusing pulses improves the sampling efficiency in 3D turbo spin echo imaging. Two flexible reordering schemes, the linear mode and the radial mode, have been proposed [1] to circumvent some intrinsic limitations of the rectangular kspace sampling grid (e.g., allowing for flexible k-space coverage) in...

متن کامل

Application of phase consistency to improve time efficiency and image quality in dual echo black-blood carotid angiography.

There is a considerable similarity between proton density-weighted (PDw) and T2-weighted (T2w) images acquired by dual echo fast spin-echo (FSE) sequences. The similarity manifests itself not only in image space as correspondence between intensities of PDw and T2w images, but also in phase space as consistency between phases of PDw and T2w images. Methods for improving the imaging efficiency an...

متن کامل

Two-point Dixon imaging with flexible echo times and a region growing-based postprocessing algorithm

Introduction: The scan time for a two-point Dixon technique using dual-echo acquisition can become comparable with that for a conventional non-Dixon technique with similar scan parameters (1, 2). Recently, Xiang and Eggers et al. showed that images with echo times that are more flexible than being in-phase and out-of-phase can be used for two-point Dixon processing (3, 4). This increased flexib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2009