Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
نویسندگان
چکیده
New technologies that utilize capillary-based immunoassays promise faster and more quantitative protein assessment compared to traditional immunoassays. However, similar to other antibody-based protein assays, optimization of capillary-based immunoassay parameters, such as protein concentration, antibody dilution, and exposure time is an important prerequisite to the generation of meaningful and reliable data. Measurements must fall within the linear range of the assay where changes in signal are directly proportional to changes in lysate concentration. The process of choosing appropriate lysate concentrations, antibody dilutions, and exposure times in the human bronchial epithelial cell line, BEAS-2B, is demonstrated here. Assay linearity is shown over a range of whole cell extract protein concentrations with p53 and α-tubulin antibodies. An example of signal burnout is seen at the highest concentrations with long exposure times, and an α-tubulin antibody dilution curve is shown demonstrating saturation. In addition, example experimental results are reported for doxorubicin-treated cells using optimized parameters.
منابع مشابه
An evaluation of the detection limits possible for competitive capillary electrophoretic immunoassays.
Using a high-affinity antibody for estradiol, thermodynamic and experimental limitations on detection limits for competitive capillary electrophoretic immunoassays were examined. Theoretical modeling of the dose-response curves for such assays allowed for optimization of experimental conditions. Through the examination of experimental and theoretical results generalizations could be made as to ...
متن کاملHomogeneous Immunoassay for Detection of Tnt and Its Analogues on a Microfabricated Capillary Array Electrophoisis Chip
A high sensitivity homogeneous immunoassay for TNT and its analogues has been developed based on the rapid electrophoretic separation of an equilibrated mixture of an anti-TNT antibody, fluorescein-labeled TNT, and unlabeled TNT or its analogue. The band intensities of the free fluorescein-labeled TNT and of the antibody-antigen complex reveal the relative equilibrated concentrations. TNT and i...
متن کاملPhotopatterned polyacrylamide gels enable efficient microfluidic protein assays
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. To copy otherwise, to republish, to post on servers or to redistribute to lists, requires prior specific permission....
متن کاملApplication of the Phenomenological Model to Electrophoretic Mobility in Mixed Solvent Electrolyte Systems in Capillary Zone Electrophoresis
The phenomenological model of Khossravi and Connors (1992) has been adopted to calculate the electrophoretic mobility of drugs at different concentrations of solvents in a binary mixture. The accuracy and predictability of the model have been evaluated employing 14 experimental data sets by using average percentage mean deviation (APMD). The obtained APMD for correlative and predictive studies ...
متن کاملDetermination of chromate adulteration of human urine by automated colorimetric and capillary ion electrophoretic analyses.
Various chemicals can be added to urine specimens collected for drug analysis to abnormally elevate ionic concentrations and/or interfere with either immunoassay urine drug-screening procedures or gas chromatographic-mass spectrometric confirmation techniques. One such adulterant, "Urine Luck" (formula 5.3), has been identified in our previous research to contain potassium dichromate. Screening...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1185 شماره
صفحات -
تاریخ انتشار 2017