Real-time detection of epileptic seizures in animal models using reservoir computing.
نویسندگان
چکیده
In recent years, an increasing number of studies have investigated the effects of closed-loop anti-epileptic treatments. Most of the current research still is very labour intensive: real-time treatment is manually triggered and conclusions can only be drawn after multiple days of manual review and annotation of the electroencephalogram (EEG). In this paper we propose a technique based on reservoir computing (RC) to automatically and in real-time detect epileptic seizures in the intra-cranial EEG (iEEG) of epileptic rats in order to immediately trigger seizure treatment. The performance of the system is evaluated in two different seizure types: absence seizures from genetic absence epilepsy rats from Strasbourg (GAERS) and limbic seizures from post status epilepticus (PSE) rats. The dataset consists of 452 hours iEEG from 23 GAERS and 2083 hours iEEG from 22 PSE rats. In the default set-up the system detects 0.09 and 0.13 false positives per seizure and misses 0.07 and 0.005 events per seizure for GAERS and PSE rats respectively. It achieves an average detection delay below 1s in GAERS and less than 10s in the PSE data. This detection delay and the number of missed seizures can be further decreased when a higher false positive rate is allowed. Our method outperforms state-of-the-art detection techniques and only a few parameters require optimization on a limited training set. It is therefore suited for automatic seizure detection based on iEEG and may serve as a useful tool for epilepsy researchers. The technique avoids the time-consuming manual review and annotation of EEG and can be incorporated in a closed-loop treatment strategy.
منابع مشابه
Epileptic seizure detection using Reservoir Computing
In this paper it is shown that Reservoir Computing can be successfully applied to perform real-time detection of epileptic seizures in Electroencephalograms (EEGs). Absence and tonic-clonic seizures are detected on intracranial EEG coming from rats. This resulted in an area under the Receiver Operating Characteristics (ROC) curve of more than 0.99 on the data that was used. For absences an aver...
متن کاملReal-Time Epileptic Seizure Detection on Intra-cranial Rat Data Using Reservoir Computing
In this paper it is shown that Reservoir Computing can be successfully applied to perform real-time detection of epileptic seizures in Electroencephalograms (EEGs). Absence and tonic-clonic seizures are detected on intracranial EEG coming from rats. This resulted in an area under the Receiver Operating Characteristics (ROC) curve of about 0.99 on the data that was used. For absences an average ...
متن کاملDetectie van epileptische aanvallen: de Reservoir Computing-benadering Detection of Epileptic Seizures: the Reservoir Computing Approach
متن کامل
مروری بر انواع مدلهای حیوانی تشنج: مقاله مروری
Nowadays, there are various animal models of acute and chronic seizures. Some chemical and electrical models such as seizure induced by pentylenetetrazol injection and maximum electric shock has been developed over of six decades and different kinds of chemical, electrical and genetic models have been admitted up to now. Among chemical models of seizure induction penicillin, bicuculline, tetanu...
متن کاملEpileptic Seizure Detection in EEG signals Using TQWT and SVM-GOA Classifier
Background: Epilepsy is a Brain disorder disease that affects people's quality of life. If it is diagnosed at an early stage, it will not be spread. Electroencephalography (EEG) signals are used to diagnose epileptic seizures. However, this screening system cannot diagnose epileptic seizure states precisely. Nevertheless, with the help of computer-aided diagnosis systems (CADS), neurologists ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Epilepsy research
دوره 103 2-3 شماره
صفحات -
تاریخ انتشار 2013