Clinical evaluation of defibrillation testing in an unselected population of 2,120 consecutive patients undergoing first implantable cardioverter-defibrillator implant.

نویسندگان

  • Michele Brignole
  • Eraldo Occhetta
  • Maria Grazia Bongiorni
  • Alessandro Proclemer
  • Stefano Favale
  • Saverio Iacopino
  • Leonardo Calò
  • Antonello Vado
  • Gianfranco Buja
  • Giosuè Mascioli
  • Fabio Quartieri
  • Massimo Tritto
  • Umberto Parravicini
  • Antonio Castro
  • Corrado Tomasi
  • Giovanni Quinto Villani
  • Matteo Giuseppe D'Acri
  • Catherine Klersy
  • Maurizio Gasparini
چکیده

OBJECTIVES The purpose of this study is to assess the effectiveness of defibrillation testing (DT) in patients undergoing implantable cardioverter-defibrillator (ICD) insertion. BACKGROUND Although DT is considered a standard procedure during ICD implantation, its usefulness has not been definitively proven. METHODS The SAFE-ICD (Safety of Two Strategies of ICD Management at Implantation) study is a prospective observational study designed to evaluate the outcome of 2 strategies: performing defibrillation testing (DT+) versus not performing defibrillation testing (DT-) during de novo ICD implants. No deviation from the centers' current practice was introduced. In all, 2,120 consecutive patients (836 DT+ and 1,284 DT-) age ≥18 years were enrolled at 41 Italian centers from April 2008 to May 2009 and followed up for 24 months until June 2011. The primary endpoint was a composite of severe complications at ICD implant and sudden cardiac death or resuscitation at 2 years. RESULTS The primary endpoint occurred in 34 patients: 12 intraoperative complications (8 in DT+ group; 4 in DT- group) and 22 during follow-up (10 in DT+ group; 12 in DT- group). Overall, the estimated yearly incidence (95% confidence interval) was DT+ 1.15% (0.73 to 1.83) and DT- 0.68% (0.42 to 1.12). The difference between the 2 groups was negligible: 0.47% per year (-0.15 to 1.10). Mortality from any cause was similar at 2 years (adjusted hazard ratio: 0.97 [0.76 to 1.23], p = 0.80). CONCLUSIONS In this large cohort of new ICD implants, event rates were similar and extremely low in both groups. These data indicate a limited clinical relevance for DT testing, thus supporting a strategy of omitting DT during an ICD implant. (Safety of Two Strategies of ICD Management at Implantation [SAFE-ICD]; NCT00661037).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Automated vulnerability testing identifies patients with inadequate defibrillation safety margin.

BACKGROUND Implantable cardioverter-defibrillator system efficacy is tested at implant by induction of ventricular fibrillation (VF). Defibrillation safety margin can be assessed without VF induction using upper limit of vulnerability methods, but these methods have required manual determination of T-wave timing. METHODS AND RESULTS To test the feasibility of an inductionless system of implan...

متن کامل

Comparison of outcomes in patients undergoing defibrillation threshold testing at the time of implantable cardioverter-defibrillator implantation versus no defibrillation threshold testing.

BACKGROUND Inability to perform defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantation due to co-morbidities may influence long-term survival. METHODS Retrospective review at The University of Michigan (1999-2004) identified 55 patients undergoing ICD implantation without DFT testing ("No-DFT group"). A randomly selected sample of patients (n =...

متن کامل

Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.

BACKGROUND The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 60 11  شماره 

صفحات  -

تاریخ انتشار 2012