Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T

نویسندگان

  • Jingkun Wang
  • Yizhen Fang
  • Peihua Li
  • Huayue Lin
  • Hongwei Jin
  • Lei Gao
  • Shengxiang Ge
  • Zhong-Ying Zhang
چکیده

BACKGROUND To evaluate the performance of a chemiluminescence detection kit for cardiac troponin T (cTnT). METHODS According to the "Guiding principles on performance analysis of diagnostic reagents in vitro" and the Clinical and Laboratory Standards Institute (CLSI) Guidelines, we assessed the detection limit, linear range, reportable range, accuracy, precision, cross reactivity, interference factors, and matrix effect of the kit, and compared these parameters with that of the commercial electrochemiluminescence detection kit for cTnT (Roche). RESULTS The minimum detection limit of the kit was 0.01 ng/mL. The linear range was 0.01 ng/mL-25 ng/mL. The reportable range was from 0.01 ng/mL to 100 ng/mL. Precision within the batch was 2.9%-6.4%, and precision between batches was 6.0%; the accuracy was good and the recovery rate reached 96.2%. The cross-reaction test demonstrated that there was no reactivity between cTnT and a variety of troponins. Test results deviated by less than ±10% in the presence of hemoglobin ≤1000 μg/mL, bilirubin ≤250 μg/mL, triglycerides ≤11.25 mg/mL, and rheumatoid factor ≤206 U/mL, suggesting that kit results were not significantly interfered with these factors. Results from the matrix-effect assessment revealed absence of a matrix effect in the tested serum samples. Correlation study revealed that the performance of the kit was very consistent with that of the Roche electrochemiluminescence detection kit (Kappa = 0.900, P < .001) with a high correlation (r = .903, P < .001) and a total matching rate of 95.00%. CONCLUSION The performance of the evaluated chemiluminescence immunoquantitation kit for cTnT detection was acceptable in all tested parameters, fulfilling requirements for clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn&rsquo;t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

Diagnostic efficiency of troponin T measurements in acute myocardial infarction.

BACKGROUND The present study was designed to evaluate the efficiency of a newly developed troponin T enzyme immunoassay for the detection of acute myocardial infarction. METHODS AND RESULTS The study comprised 388 patients admitted with chest pain and suspected myocardial infarction and 101 patients with skeletal muscle damage and additional suspected myocardial cell damage. Troponin T was el...

متن کامل

Significance of Cardiac Troponin T Release in Detecting Minor Myocardial Injury After Percutaneous Transluminal Coronary Angioplasty

649 Abstract: Cardiac Troponin T (TnT) is a regulatory contractile protein not normally found in blood. Its detection in the circulation has been shown to be a sensitive and specific marker for myocardial cell damage. This study was designed to evaluate the diagnostic efficiency of TnT enzyme immunoassay in detecting myocardial damage in patients with stable angina pectoris undergoing visually ...

متن کامل

Recent Advances in Point-of-Care Diagnostics for Cardiac Markers

National and international cardiology guidelines have recommended a 1-hour turnaround time for reporting results of cardiac troponin to emergency department personnel, measured from the time of blood collection to reporting. Use of point-of-care testing (POCT) can reduce turnaround times for cardiac markers, but current devices are not as precise or sensitive as central laboratory assays. The g...

متن کامل

Correlation between the Level of Creatinine, Serum Cardiac Troponines and Left Ventricle Function Tests in Patients with Chronic Renal Diseases without Acute Coronary Syndrome

Background and Objectives:  The aim of this study was to survey the relationship between the level of  creatinine,cardiac troponins serum and the function of  the left ventricle in patients with  kidney insufficiency,without acute coronary syndrome. Materialsand Methods:The sample  was150 patients with nondialysis chronic kidney disease without  acute  coronary  syndrome,  hospitalized  at  I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2018