A model for the harmonisation of test results of different quantitative D-dimer methods.
نویسندگان
چکیده
The numerical test results of different D-dimer assays vary widely. Because of the complexity of the analyte of target as well as the variability in specificity of different D-dimer assays, only harmonisation of the test results seems to be feasible. The use of a single conversion factor does not take into account for several methods the lack of commutability between test results and consensus values at different D-dimer levels. This is probably related to the mutually different response of methods to high and low levels. We therefore designed a harmonisation model based on the transformation of a method-specific regression line to a reference regression line. We used the data for the measurement of a set of plasma samples with different D-dimer levels by 353 different laboratories using 7 of the most frequently used quantitative D-dimer methods. For each method we calculated the method-specific consensus value for each sample. The overall median value was also estimated. Per method linear regression was applied throughout the method-specific consensus values using the amount of patient pooled plasma added to the different plasma samples as the independent variable. The line through the overall median values of all 7 methods was used as the reference line. Harmonisation between the methods was obtained by transformation of the method-specific regression line to the reference line. This harmonisation resulted in a reduction of the variability between the method-specific consensus values from about 75% to about 5.5%. Clinical validation of this concept had shown significant improvement of the test result comparability. We conclude that this model is a feasible approach in the harmonisation of D-dimer methods. If the harmonisation procedure is included in the calibration procedure by the manufacturers, customers will automatically obtain harmonised test results.
منابع مشابه
The Effect of Preanalytical, Analytical, and Postanalytical Variables on D-dimer Measurement
D-dimer is a soluble fibrin degradation product deriving from the plasmin-mediated degradation of cross-linked fibrin. D-dimer can hence be considered a biomarker of activation of coagulation and fibrinolysis, and it is routinely used for ruling out venous thromboembolism (VTE). D-dimer is increasingly used to assess the risk of VTE recurrence and to help define the uoptimal duration of anticoa...
متن کاملEvaluation of Correlation between D-dimer Levels with Disease Severity in Patients with Covid-19 Referred to Hamedan Besat Hospital in 2021-2022
Introduction: The Covid-19 virus affects the hemostasis system in infected people by causing thrombosis and it increases the level of D_dimer. This study was designed and conducted for the evaluation of correlation between D-dimer levels with disease severity in patients with Covid-19 referred to Hamedan Besat hospital. Methods and Materials: 366 patients with Covid-19 referred to Besat Hospit...
متن کاملAcute Phase Reactants as a Prognostic Factor in Acute Stroke
Introduction: Elevated levels of CRP are present among patients at risk for further first-ever myocardial infarction and stroke. It has been shown that after ischemic stroke, increased levels of CRP are associated with unfavorable outcomes. Methods: From 120 patients admitted to the emergency unit of our hospital with the diagnosis of stroke CRP, D-dimer and ferritin level was measured and the ...
متن کاملPlasma Fibrinogen and D-dimer in Children With Sepsis: A Single-center Experience
Background & Objectives: In sepsis, enhanced fibrin formation, impaired fibrin degradation, and intravascular fibrin deposition lead to a prothrombotic state. The current study aimed at measuring various coagulation parameters to predict an early marker for disseminated intravascular coagulation (DIC). Methods: The current prospective s...
متن کاملتاثیر دوازده هفته تمرینات ورزشی ترکیبی (قدرتی، استقامتی، پیلاتس و PNF) بر سطوح فیبرین دی دایمر (FDD) و اینترلوکین-6 در بیماران زن مبتلا به مولتیپل اسکلروزیس با درجات مختلف ناتوانی
Background and Objective: Multiple Sclerosis (MS) is a neurological disorder that can restrict individual's ability to carry on their activities. The[J1] aim of this study was to examine the effects of combined exercise training on serum Fibrin D-Dimer (FDD) and interleukin-6 in female multiple sclerosis patients with different levels of disability. Materials and Methods: 96 female patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thrombosis and haemostasis
دوره 95 3 شماره
صفحات -
تاریخ انتشار 2006