Single Echo Simultaneous Angiography and Venography (MRAV) Techniques at 3T
نویسندگان
چکیده
Introduction: Several techniques have been presented in the last year to acquire both angiographic and venographic information in a single acquisition (MRAV) using susceptibility weighted imaging (SWI). However, these techniques either require a double echo acquisition (1) or a single echo with flip angles that tend to compromise the quality of either the angiography or venography (2). In this work we develop novel acquisition and post processing techniques to improve the quality of single echo MRAV acquisition. The ability to collect MRAV data is an important clinical goal for analyzing a variety of clinical diseases including: stroke, trauma, tumors and multiple sclerosis.
منابع مشابه
Simultaneous Angiography and Venography Techniques Compared at 7T
Introduction: Two techniques have been presented in the last year to acquire both angiographic and venographic information in a single acquisition (MRAV) using susceptibility weighted imaging (SWI). One uses a double echo approach with the shorter echo used for the angiography and the longer echo used for the venography (1). The other uses a single echo that is a compromise between the two with...
متن کامل3T high-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with parallel imaging.
The diagnostic image quality of contrast-enhanced (CE) 3D MR venography (MRV) was prospectively compared with that of 2D time-of-flight (TOF) MRV and contrast-enhanced 3D magnetization-prepared rapid acquisition of gradient echo (MPRAGE) sequences for the visualization of the intracranial venous system at 3T in 22 patients. CE MRV provides high-quality images and was shown to be superior to TOF...
متن کاملContinuously Moving Table Mr Imaging at 3t: a Comparison to 1.5t
INTRODUCTION In the last years, continuously moving table (CMT) acquisition techniques have been developed to efficiently acquire extended Fields of View (FoV). Clinical relevance of these techniques, especially for cancer patients, has been reported [1-3] and CMT acquisitions are used in our daily clinical routine for metastases screening at 1.5T. However, 3T scanners are getting more and more...
متن کاملImprovement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising
The vein structures of the brain are important for understanding brain function and structure, especially when functional magnetic resonance imaging (fMRI) is utilized, as fMRI is based on changes in the blood-oxygen-level-dependent (BOLD) signal, which is directly related to veins. The aim of the present study was to develop an effective method to produce high signal-to-noise-ratio (SNR) and h...
متن کاملMulti-Shot, Diffusion-Weighted Imaging at 3T using Readout-Segmented EPI and GRAPPA
D. A. Porter, R. M. Heidemann MR Applications Development, Siemens Medical Solutions, Erlangen, Germany Introduction Diffusion-weighted, single-shot EPI suffers from considerable susceptibility-based distortion artefact at 3T. Although the effects can be mitigated by using a partially parallel imaging (PPA) technique to reduce the effective echo-spacing [1], there are significant residual artef...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008