Dynamic disorder in single-enzyme experiments: facts and artifacts.

نویسندگان

  • Tatyana G Terentyeva
  • Hans Engelkamp
  • Alan E Rowan
  • Tamiki Komatsuzaki
  • Johan Hofkens
  • Chun-Biu Li
  • Kerstin Blank
چکیده

Using a single-molecule fluorescence approach, the time series of catalytic events of an enzymatic reaction can be monitored, yielding a sequence of fluorescent "on"- and "off"-states. An accurate on/off-assignment is complicated by the intrinsic and extrinsic noise in every single-molecule fluorescence experiment. Using simulated data, the performance of the most widely employed binning and thresholding approach was systematically compared to change point analysis. It is shown that the underlying on- and off-histograms as well as the off-autocorrelation are not necessarily extracted from the "signal'' buried in noise. The shapes of the on- and off-histograms are affected by artifacts introduced by the analysis procedure and depend on the signal-to-noise ratio and the overall fluorescence intensity. For experimental data where the background intensity is not constant over time we consider change point analysis to be more accurate. When using change point analysis for data of the enzyme α-chymotrypsin, no characteristics of dynamic disorder was found. In light of these results, dynamic disorder might not be a general sign of enzymatic reactions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Disorder in Single Enzyme Reactions: Facts and Artifacts

Title Dynamic Disorder in Single-Enzyme Experiments: Facts and Artifacts Author(s) Terentyeva, Tatyana G.; Engelkamp, Hans; Rowan, Alan E.; Komatsuzaki, Tamiki; Hofkens, Johan; Li, Chun-Biu; Blank, Kerstin Citation ACS Nano, 6(1): 346-354 Issue Date 2012-01-24 Doc URL http://hdl.handle.net/2115/51590 Right This document is the Accepted Manuscript version of a Published Work that appeared in fin...

متن کامل

Assessment of Diagnostic Value of Single View Dynamic Technique in Diagnosis of Developmental Dysplasia of Hip: A Comparison with Static and Dynamic Ultrasond Techniques

   Background: Developmental dysplasia of hip (DDH) is a common childhood disorder, and ultrasonography examination is routinely used for screening purposes. In this study, we aimed to evaluate a modified combined static and dynamic  ultrasound technique for the detection of DDH and to compare with the results of static and dynamic ultrasound techniques.    Methods:In this cross-sectional study...

متن کامل

Immediate effect of Mulligan knee taping on pain, knee dynamic valgus, and landing kinetic in physically active female with patellofemoral pain

 Aims and background: Inappropriate kinetic and kinematic are considered as effective factors in knee injuries especially patellofemoral pain. The aim of this study was to investigate the immediate effect of Mulligan taping on knee dynamic valgus, maximum knee flexion angle, the maximum ground reaction force, time to stabilization and pain in physically active female with patellofemoral pain an...

متن کامل

Dynamic Multi-Objective Navigation in Urban Transportation Network Using Ant Colony Optimization

Intelligent Transportation System (ITS) is one of the most important urban systems that its functionality affects other urban systems directly and indirectly. In developing societies, increasing the transportation system efficiency is an important concern, because variety of problems such as heavy traffic condition, rise of the accident rate and the reduced performance happen with the rise of p...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ACS nano

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2012