A Case of a Zotarolimus-Eluting Stent Fracture in the Left Anterior Descending Artery in a Patient Undergoing Hemodialysis

نویسندگان

  • In Hye Cha
  • Seong Hwan Kim
  • Sang Yup Lim
  • Jeong Chun Ahn
  • Woo Hyuk Song
چکیده

Although stent fracture after implantation of a drug-eluting stent (DES) is a rare complication, it has been suggested to be a cause of restenosis. To date, most DES fractures have been associated with sirolimus-eluting stents. We describe here a case of a zotarolimus-eluting stent fracture after 8 months of stent placement in a calcified left anterior descending artery lesion in a patient undergoing hemodialysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sirolimus-Versus Zotarolimus-Eluting Stents in Acute Coronary Syndromes With C Type Left Anterior Descending Artery Lesions: A Three-Year Clinical Follow-Up

BACKGROUND Drug-eluting stents have improved the efficacy of percutaneous coronary intervention and made it the preferred therapy in the treatment of ischemic heart diseases including acute coronary syndromes. The objective of the study was to compare the clinical efficacy and safety of sirolimus-eluting stent with that of zotarolimus-eluting stent following percutaneous coronary intervention f...

متن کامل

Subacute thrombosis following implantation of zotarolimus-eluting stent.

Endeavor (Medtronic Europe SA) is a new zotarolimus-eluting stent with a favourable safety profile reported in early trials. We report a case of subacute thrombosis following deployment of an Endeavor stent in the distal left anterior descending coronary artery, despite optimum loading with and continuation of clopidogrel therapy as well as previous administration of a IIb/IlIa inhibitor.

متن کامل

Simultaneous Multi-Vessel Subacute Stent Thromboses in Zotarolimus-Eluting Stents

Despite its low incidence, stent thrombosis (ST) is one of the most dreaded complications of percutaneous coronary intervention. Endeavor (Medtronics Europe SA) is a new zotarolimus-eluting stent (ZES) with a favorable safety profile that was reported in early and ongoing trials. However, few lethal stent thromboses related to this new drug eluting stent (DES) have been reported. We experienced...

متن کامل

Multiple Sequential Complications After Sirolimus-Eluting Stent Implantation: Very Late Stent Thrombosis, Stent Fracture, In-Stent Restenosis, and Peri-Stent Aneurysm

A 55-year-old male patient presented with an acute myocardial infarction. A sirolimus-eluting stent (SES) was implanted in the proximal left anterior descending artery (LAD). Eight months later, there was a newly developed distal LAD lesion. An additional SES was implanted. Twenty-eight months after the index procedure of primary coronary intervention, the electrocardiogram showed ST elevation ...

متن کامل

A Rare Case of Double Myocardial Bridges of the Left Anterior Descending Artery

Myocardial bridge is a benign congenital anomaly in which a segment of major epicardial coronary arteries descends into the myocardium for a variable distance. Myocardial bridge is most often single and located in the middle part of the left anterior descending artery. The presence of more than one myocardial bridge in coronary arteries is very rare. We present a patient with more than one myoc...