Flexible active electrode arrays with ASICs that fit inside the rat’s spinal canal

نویسندگان

  • Vasiliki Giagka
  • Andreas Demosthenous
  • Nick Donaldson
چکیده

Epidural spinal cord electrical stimulation (ESCS) has been used as a means to facilitate locomotor recovery in spinal cord injured humans. Electrode arrays, instead of conventional pairs of electrodes, are necessary to investigate the effect of ESCS at different sites. These usually require a large number of implanted wires, which could lead to infections. This paper presents the design, fabrication and evaluation of a novel flexible active array for ESCS in rats. Three small (1.7 mm(2)) and thin (100 μm) application specific integrated circuits (ASICs) are embedded in the polydimethylsiloxane-based implant. This arrangement limits the number of communication tracks to three, while ensuring maximum testing versatility by providing independent access to all 12 electrodes in any configuration. Laser-patterned platinum-iridium foil forms the implant's conductive tracks and electrodes. Double rivet bonds were employed for the dice microassembly. The active electrode array can deliver current pulses (up to 1 mA, 100 pulses per second) and supports interleaved stimulation with independent control of the stimulus parameters for each pulse. The stimulation timing and pulse duration are very versatile. The array was electrically characterized through impedance spectroscopy and voltage transient recordings. A prototype was tested for long term mechanical reliability when subjected to continuous bending. The results revealed no track or bond failure. To the best of the authors' knowledge, this is the first time that flexible active electrode arrays with embedded electronics suitable for implantation inside the rat's spinal canal have been proposed, developed and tested in vitro.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

Flexible Microfabricated Parylene Multielectrode Arrays for Retinal Stimulation and Spinal Cord Field Modulation

The first flexible parylene-based multielectrode arrays (MEAs) designed for functional electrical stimulation (FES) in retinal prostheses, and the extension of this technology toward enabling reflex-arc neuromodulation in cases of spinal cord damage or transection, are presented. A single metal layer 16 ×16 retinal electrode array of 125 μm-diameter thin-film Ti/Pt electrodes and lines of 12 μm...

متن کامل

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

Assessment of corelation between spinal canal shape and spinal cord injury in thoracolumbar spine fractures

Traumatic spinal cord injury is one of the important causes of disability.in some of vertebral fractures,spinal canal is deformed and compromised.the relationship between the shape of the cervical canal and spinal cord hnjury has been proved but such a correlation for thoraculombar spine 50 patients with compromised canal(cases) and 50 oatients with intact canal were evaluated in the light of s...

متن کامل

Neuroelectronic Interfacing With Cultured Multielectrode Arrays Toward a Cultured Probe

Efficient and selective electrical stimulation and recording of neural activity in peripheral, spinal, or central pathways requires multielectrode arrays at micrometer scale. At present, wire arrays in brain, flexible linear arrays in the cochlea and cuff arrays around nerve trunks are in experimental and/or clinical use. Twoand three-dimensional brush-like arrays and sieve arrays, with around ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015