Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty.

نویسندگان

  • S Abboud
  • R J Cohen
  • A Selwyn
  • P Ganz
  • D Sadeh
  • P L Friedman
چکیده

Electrocardiographic manifestations of transient myocardial ischemia were studied, in 11 patients undergoing angioplasty (PTCA) of a left anterior descending coronary artery stenosis, by the visual inspection of the standard surface electrocardiogram (S-ECG) and the intracoronary ECG (IC-ECG) as well as computer-assisted analysis of the S-ECG. Cross-correlation analysis (CCA) performed by computer was used to compare beat-to-beat variability in ST-T morphology of the S-ECG during different stages of PTCA. CCA was also applied to the signal-averaged high-frequency QRS (SA-HFQ). All patients developed angina during balloon inflation, accompanied by transient marked ST-T changes in IC-ECG in 10 of 11 patients (90%). Visual inspection of S-ECG revealed transient ST-T changes in only 6 of 11 (54%). In contrast, CCA of the S-ECG revealed transient ST-T changes in 9 of 11 (82%). Analysis of SA-HFQ revealed that balloon inflation was associated with a marked reduction in the calculated root-mean-square (RMS) voltage for such signals (2.31 +/- 1.04 microV) as compared with RMS values before (3.27 +/- 1.12 microV, p less than .05) PTCA or after conclusion of PTCA (3.79 +/- 1.39 microV, p less than .01). Balloon inflation was also accompanied by changes in waveform morphology of the SA-HFQ, including the development of new or more prominent time zones of reduced amplitude in 10 of 11 individuals (90%). Such zones may represent slow conduction in regions of the heart rendered ischemic during PTCA. CCA of the S-ECG and of SA-HFQ appears to detect evidence of transient ischemia with greater sensitivity than simple visual inspection of S-ECG, and may therefore prove to be of use in the evaluation of patients with chest pain of uncertain origin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The value of myocardial perfusion imaging with Tc-99m MIBI for the prediction of perfusion improvement after percutaneous transluminal coronary angioplasty

  Introduction: Percutaneous transluminal coronary angioplasty (PTCA) is an effective method for revascularizing of stenotic coronary vessels. Lack of response to this treatment, either in symptomatic or asymptomatic patients, is usually due to incomplete revascularization, restenosis, and/or irreversibility of myocardial perfusion. Introduction of a noninvasive metho...

متن کامل

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...

متن کامل

Value of the intracoronary electrocardiogram to monitor myocardial ischemia during percutaneous transluminal coronary angioplasty.

To enhance detection of ischemia during percutaneous transluminal coronary angioplasty (PTCA), unipolar intracoronary electrocardiograms (ECGs) were recorded during PTCA in 25 patients from the tips of guidewires positioned distal to stenoses being dilated. Surface electrocardiographic leads chosen to reflect likely areas of reversible ischemia during PTCA were recorded simultaneously. In 21 of...

متن کامل

Changes in systemic vascular resistance detected by the arterial resistometer: preliminary report of a new method tested during percutaneous transluminal coronary angioplasty.

A recently developed apparatus provides on-line continuous monitoring of systemic vascular resistance (SVR) by means of simple computer analysis of the peripheral arterial waveform. The fundamental equation of this method is Ri = P'/(dP/dt), where dP/dt is the peak dP/dt of the peripheral arterial waveform, P' is the pressure at time of peak dP/dt, and Ri is a resistance index that bears a dire...

متن کامل

Selective suction and pressure-regulated retroinfusion: an effective and safe approach to retrograde protection against myocardial ischemia in patients undergoing normal and high risk percutaneous transluminal coronary angioplasty.

OBJECTIVES We sought to study the safety, feasibility and efficacy of selective suction and pressure-regulated retroinfusion to protect against myocardial ischemia in patients undergoing normal risk and high risk balloon angioplasty. BACKGROUND In a pig model of acute myocardial ischemia it was previously shown that use of selective suction and pressure-regulated retroinfusion was able to sub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 76 3  شماره 

صفحات  -

تاریخ انتشار 1987