Estimation and application of EMG amplitude during dynamic contractions.
نویسندگان
چکیده
The sections above have described an EMG amplitude estimator and an initial application of this estimator to the EMG-torque problem. The amplitude estimator consists of six stages. In the first stage, motion artifact and power-line interference are attenuated. Motion artifact is typically removed with a highpass filter. Elimination of power-line noise is more difficult. Commercial systems tend to use notch filters, accepting the concomitant loss of "true" signal power in exchange for simplicity and robustness. Adaptive methods may be preferable, however, to preserve more "true" signal power. In stage two, the signal is whitened. One fixed whitening technique and two adaptive whitening methods were described. For low-amplitude levels, the adaptive whitening technique that includes adaptive noise cancellation may be necessary. In stage three, multiple EMG channels (all overlying the same muscle) are combined. For most applications, simple gain normalization is all that is required. Stage four rectifies the signal and then applies the power law required to demodulate the signal. In stage six, the inverse of the power law is applied to relinearize the signal. Direct comparison of MAV (first power) to RMS (second power) processing demonstrates little difference between the two. Therefore, unless there is reason to believe that the EMG density departs strongly from that found in the existing studies, RMS and MAV processing are essentially identical. In stage five, the demodulated samples are averaged across all channels and then smoothed (time averaged) to reduce the variance of the amplitude estimate, but at the expense of increasing the bias. For best performance, the window length that best trades off variance and bias error is selected. The advanced EMG processing was next applied to dynamic EMG-torque estimation about the elbow joint. Results showed that improved EMG amplitude estimates led to improved EMG-torque estimates. An initial comparison of different system-identification techniques and model orders was reported. It is expected that these advanced processing and identification algorithms will also improve performance in other EMG applications, including myoelectrically controlled prostheses, biofeedback, and ergonomic assessment.
منابع مشابه
Quantitative Assessment of Muscle Fatigue for FES Research Studies
Background: Muscle fatigue is an important issue in neuromuscular rehabilitation. Better control of this phenomenon would result in better prevention of its consequent physiological damages.Objective: To provide a mathematical representation of muscle fatigue as a function of time.Methods: We conducted this study by combining the EMG-based estimation methods of muscle activation with the availa...
متن کاملMMG and EMG responses during fatiguing isokinetic muscle contractions at different velocities.
The purpose of this study was to determine mechanomyographic (MMG) and electromyographic (EMG) responses of the superficial quadriceps muscles during repeated isokinetic contractions in order to provide information about motor control strategies during such activity, and to assess uniformity in mechanical activity (MMG) between the investigated muscles. Ten adults performed 50 maximal concentri...
متن کاملInvestigation of the EMG-time relationship of the biceps Brachii muscle during contractions
[Purpose] This study investigated the changes in the slope of EMG-time curves (relationship) at the maximal and different levels of dynamic (eccentric and concentric) and static (isometric) contractions. [Subjects and Methods] The subject was a 17 year-old male adolescent. The surface EMG signal of the dominant arm's biceps brachii (BB) was recorded through electrodes placed on the muscle belly...
متن کاملA combined muscle model and wavelet approach to interpreting the surface EMG signals from maximal dynamic knee extensions.
This study aimed to identify areas of reduced surface EMG amplitude and changed frequency across the phase space of a maximal dynamic knee extension task. The hypotheses were that (1) amplitude would be lower for eccentric contractions compared with concentric contractions and unaffected by fiber length and (2) mean frequency would also be lower for eccentric contractions and unaffected by fibe...
متن کاملStudy of the Electrically Evoked EMG and Torque Output Dur - ing the Muscle Fatigue Process in FES - Induced Static and Dy - namic Contractions
This study compared the different fatigue processes of electrically elicited static and dynamic muscle contractions of quadriceps in five paraplegic subjects. An electrodynamometer was utilized for recording the generated torque output and controlling the isokinetic dynamic movements. Stimulus-evoked electromyography (EMG), after artifact suppression, was used to observe the fatigue process. Be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society
دوره 20 6 شماره
صفحات -
تاریخ انتشار 2001