Correcting the dynamic response of a commercial esophageal balloon-catheter.

نویسندگان

  • Troy J Cross
  • Kenneth C Beck
  • Bruce D Johnson
چکیده

It is generally recommended that an esophageal balloon-catheter possess an adequate frequency response up to 15 Hz, such that parameters of respiratory mechanics may be quantified with precision. In our experience, however, we have observed that some commercially available systems do not display an ideal frequency response (<8-10 Hz). We therefore investigated whether the poor frequency response of a commercially available esophageal catheter may be adequately compensated using two numerical techniques: 1) an exponential model correction, and 2) Wiener deconvolution. These two numerical techniques were performed on a commercial balloon-catheter interfaced with 0, 1, and 2 lengths of extension tubing (90 cm each), referred to as configurations L0, L90, and L180, respectively. The frequency response of the balloon-catheter in these configurations was assessed by empirical transfer function analysis, and its "working" range was defined as the frequency beyond which more than 5% amplitude and/or phase distortion was observed. The working frequency range of the uncorrected balloon-catheter extended up to only 10 Hz for L0, and progressively worsened with additional tubing length (L90 = 3 Hz, L180 = 2 Hz). Although both numerical methods of correction adequately enhanced the working frequency range of the balloon-catheter to beyond 25 Hz for all length configurations (L0, L90, and L180), Wiener deconvolution consistently provided more accurate corrections. Our data indicate that Wiener deconvolution provides a superior correction of the balloon-catheter's dynamic response, and is relatively more robust to extensions in catheter tube length compared with the exponential correction method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials

The measurement of esophageal pressure allows for the calculation of several important and clinically useful parameters of respiratory mechanics. Esophageal pressure is often measured with balloon-tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, it is important to determine whet...

متن کامل

Successful Use of Biliary Duct Balloon Dilator in Repairing Post-Surgical Esophageal Stricture in premature infant

Congenital esophageal atresia needs to be surgically corrected as soon as possible. Some will present with post surgical stricture that needs to be dilated by a balloon dilator. This procedure is difficult in premature born due to infant esophageal size and availability of equipments. We herby report the first case in a premature infant with post surgical esophageal stricture of esophageal atre...

متن کامل

O-32: Pain Experienced during Sonohysterography :Cervical to Uterine Catheter Placement

Background: The aim of this study is to evaluate whether the location of the balloon placement into either the cervical canal or uterine cavity during sonohysterography can affect the intensity of pain. Materials and Methods: A total of 300 infertile women undergoing sonohysterography were randomized to intracervical or intrauterine balloon placement. The examination was scheduled in the early ...

متن کامل

Effect of esophageal distension on gastric secretions in rat and the possible mechanism

Introduction: The effect of esophageal distension (ED) on gastric motility has been well documented, but a few investigations have been carried out on the effect of ED on gastric secretion. The aim of this study was to investigate the effect of ED on gastric acid and pepsin secretion and the mechanism(s) involved. Methods: Male adult Wistar rats (200-240 g) were anesthetized with urethane (1...

متن کامل

Comparison of the Effects of Intralipid 10% and 20% on Peripheral Catheter Ablation in a Pediatric Intensive Care Unit

Background: Energy deficit is a common and serious problem in pediatric intensive care units. Parenteral nutrition, either alone or in combination with enteral nutrition, can improve nutrient delivery in critically ill patients by preventing or correcting the energy deficit and improving the outcomes. Intralipid 10% and 20% are lipid emulsions, widely used in parenteral nutrition. Despite sever...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 121 2  شماره 

صفحات  -

تاریخ انتشار 2016