Pacemaker and defibrillator lead extraction.
نویسندگان
چکیده
Surgically implanted cardiac devices play an important role in the treatment of heart disease. In the 50 years since the first pacemaker was implanted, technology has improved dramatically, and these devices have saved or improved the quality of countless lives. Pacemakers treat slow heart rhythms by increasing the heart rate or by coordinating the heart’s contraction for some heart failure patients.1 Implantable cardioverter defibrillators stop dangerous rapid heart rhythms by delivering an electric shock.2 As the range of applications widens, the number of patients with cardiac devices continues to increase. Approximately 400 000 devices are implanted each year in the United States, and there 3 million patients with implanted cardiac devices currently. Occasionally, pacemaker and implantable cardioverter defibrillator systems must be removed. The removal of such systems is potentially a high-risk procedure. With the increasing number of implanted devices, removal is required more frequently. To ensure patient safety, the Heart Rhythm Society has published guidelines for safe lead removal or extraction. These guidelines outline the indications for lead extraction, physician qualifications and training, and the tools and techniques used in the procedure.3 One part of the system is the pulse generator, a metal can that contains electric circuits and a battery, usually placed under the skin on the chest wall beneath the collarbone. To replace the battery, the pulse generator must be changed by a simple surgical procedure every 5 to 10 years. The other parts are the wires, or leads, which run between the pulse generator and the heart. In a pacemaker, these leads allow the device to increase the heart rate by delivering small bursts of electric energy to make it beat faster. In a defibrillator, the lead has special coils to allow the device to deliver a highenergy shock and convert dangerous rapid rhythms (ventricular tachycardia or fibrillation) back to a normal rhythm. For both of these functions, leads must be in contact with heart tissue. Most leads pass through a vein under the collarbone that connects to the right side of the heart (right atrium and right ventricle). To remain attached to the heart muscle, most leads have either a small screw or hooks at the end. Within a few months, the body’s natural healing process forms scar tissue along the lead and at its tip, which fastens it even more securely in the patient’s body. Leads usually last longer than device batteries, so leads are simply reconnected to each new pulse generator (battery) at the time of replacement.
منابع مشابه
Pacemaker lead endocarditis with hiccups (Kalayci)
Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...
متن کاملCase Image: Unexpected cause of lead fracture: A stylet left inside the right ventricular pacemaker lead.
A 55-year-old female patient with earlier diagnosis of cardiac cirrhosis and mitral valve implantation was admitted with complaints of weakness and dizziness. She had undergone VVIR pacemaker implantation 9 years earlier due to low ventricular rate atrial fibrillation and had generator replacement procedure 3 months previously. Electrocardiogram indicated pacemaker dysfunction due to failure to...
متن کاملPercutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads
BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...
متن کاملSuccessful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system.
A new pacing lead extraction system (VascoExtor, VascoMed, Germany) with a universally applicable locking stylet was used over a period of 12 months to extract 25 permanent pacemaker leads (mean implantation time 3.9 +/- 3.8 years) in 16 patients who had pacemaker infection (n = 13), lead dysfunction (n = 2), or before an automatic defibrillator implant (n = 1). With use of this system, we were...
متن کاملTransvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience
OBJECTIVE In recent years there has been an increase in clinical situations requiring lead extraction procedures of implanted cardiac devices. In our clinic, extraction procedures are performed with Evolution® mechanical lead extraction system. In this manuscript we aimed to evaluate our lead extraction procedures. METHODS We retrospectively evaluated lead extraction procedures carried out on...
متن کامل[Initial experience with excimer laser-assisted pacemaker and defibrillator lead extraction].
Explantation of chronically implanted pacemaker or defibrillator leads can be technically demanding. We present the results of the first 44 leads extracted with excimer laser sheaths in 25 patients with a median lead implantation time of 7 years (range: 2 to 20 years). Indications for extraction were lead fracture in 17 patients, pocket infection in 4, septicemia in 2, and lead endocarditis in ...
متن کاملذخیره در منابع من