Identification of cross-sectional parameters of lateral meniscal allografts that predict tibial contact pressure in human cadaveric knees.

نویسندگان

  • Arthur Huang
  • M L Hull
  • Stephen M Howell
  • Tammy Haut Donahue
چکیده

To guide the development of improved procedures for selecting meniscal allografts, the objective of this study was to identify which cross-sectional parameters of a lateral meniscal allograft predict the contact pressure of the articular surface of the tibia. To meet the objective, the contact pressure of the articular surface of the tibia was measured with a lateral meniscal autograft and a lateral meniscal allograft using pressure sensitive film in 15 fresh-frozen human cadaveric knees. Allografts were matched only in transverse dimensions to the autograft but not in cross-sectional dimensions. Knees were loaded to 1200 N in compression at flexion angles of 0, 15, 30 and 45 degrees using a load application system that allowed unconstrained motion in the remaining degrees of freedom. Five cross-sectional parameters for both of the grafts in each of the anterior, middle, and posterior regions were derived from measurements obtained using a laser-based non-contacting three-dimensional coordinate digitizing system (3-DCDS) (Haut et al., J. Orthop Res, 2000). Five contact variables (i.e. the maximum pressure, mean pressure, contact area, and anterior-posterior and medial-lateral locations of the centroid of contact area) were determined from the pressure sensitive film. When each allograft was paired with the corresponding autograft, the root mean squared percent differences for the cross-sectional parameters ranged from a minimum of 28% for the width of the posterior region to 572% for the height of the posterior region. The root mean squared percent differences between the contact variables for paired grafts were 29% for the maximum pressure, 19% for the mean pressure, and 24% for the contact area. Differences in the cross-sectional parameters between the grafts were related to differences in the contact variables using regression analysis. Difference in the width was most often a predictor variable in the regression models with R2 values > or = 0.45. Differences in all of the four remaining cross-sectional parameters were also important predictor variables. Because failure to match cross-sectional parameters causes substantial difference in contact variables between an allograft and autograft and because cross-sectional parameters predict the contact pressure on the tibial plateau, protocols used to prospectively select allografts should concentrate on matching cross-sectional parameters and particularly the width to those of the original meniscus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints.

BACKGROUND A mismatch of the original lateral meniscus and a lateral meniscus allograft by inaccurate preoperative radiographic sizing can have significant consequences on ultimate function. HYPOTHESIS The size of a lateral meniscal allograft affects the contact mechanics of the femoral condyle on the tibial plateau. STUDY DESIGN Controlled laboratory study. METHODS Four right and 2 left ...

متن کامل

The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: a study in human cadaveric knees.

This study addressed the question of whether the level of compressive load would affect the conclusions from statistical analyses aimed at determining how well a lateral meniscal autograft restores tibial contact (as indicated by the maximum contact pressure, mean pressure, and contact area) to that of the intact knee. If statistical analyses indicated that normal tibial contact was not restore...

متن کامل

The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci.

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements have been studied. A number of biomechanical criteria may be important for a meniscal replacement to restore normal tibiofemoral contact pressure in the knee joint and hence be clinically successful. One of these criteria is geometric similarity. The ob...

متن کامل

New algorithm for selecting meniscal allografts that best match the size and shape of the damaged meniscus.

Procedures used by tissue banks in selecting meniscal allografts that will best restore normal contact pressure at the time of surgical implantation into a recipient's knee should be improved. Our objective was to develop regression equations that use dimensions measured from magnetic resonance (MR) images of the contralateral knee to predict values of important meniscal parameters of the injur...

متن کامل

How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 124 5  شماره 

صفحات  -

تاریخ انتشار 2002