Generation of a single pulmonary pressure-volume curve does not durably affect oxygenation in patients with acute respiratory distress syndrome
نویسندگان
چکیده
INTRODUCTION It is possible that taking a static pressure-volume (PV) measurement could durably affect oxygenation and thus interfere with early evaluation of a therapeutic intervention delivered just after that measurement. The aim of the present study was to investigate the effects over time of a single static PV measurement on gas exchange and haemodynamics; the PV measurements were taken using a super syringe and by using the constant flow method in patients with acute respiratory distress syndrome. METHOD We conducted a prospective, randomized and controlled interventional study in an intensive care unit. The study was conducted in 17 patients with early acute respiratory distress syndrome ventilated with a tidal volume of 6.9 +/- 1.0 ml/kg, a plateau pressure of 27 +/- 7 cmH2O and a positive end-expiratory pressure [PEEP] of 10 cmH2O. They were all evaluated for 1 hour after each of the following two measurements was taken and during a control period (in a randomized order): generation of a PV curve using a 2 l super syringe (PVSS; insufflated volume = 1824 +/- 381 ml, plateau pressure = 46 +/- 9 cmH2O); and generation of a PV curve using the constant flow method on the ventilator (PVCF; insufflated volume = 1120 +/- 115 ml in zero end-expiratory pressure after 20 s expiratory pause, plateau pressure = 46 +/- 11 cmH2O). The maximal airway pressure allowed during PV measurement was 60 cmH2O. PEEP was set to 10 cmH2O immediately after PV measurement. Partial arterial oxygen tension (Pao2), partial carbon dioxide tension (Paco2) and mean arterial pressure were recorded each minute. RESULTS PV measurement did not significantly affect Pao2, Paco2, mean arterial pressure and lung mechanics. Two patients exhibited a sustained increase in Pao2 by more than 20% after PVCF (>60 minutes). Two patients exhibited a decrease in Pao2 by more than 20% after PVSS, which was sustained in one. These latter patients had an upper inflection point identified on the PV curve. After PVSS, Paco2 increased by more than 10 mmHg in two patients and returned to baseline values after 15 minutes. One patient exhibited a decrease in mean arterial pressure by more than 10 mmHg for less than 5 minutes after PVSS and one patient after PVCF. CONCLUSION Evaluation of the effects of a strategy aimed at improving oxygenation can be reliably recorded early after a single PV measurement that is not followed by a change in PEEP level. PV measurement using the constant flow method improves oxygenation in a limited number of patients.
منابع مشابه
Acute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report
Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...
متن کاملRecruitment in Pulmonary and Extrapulmonary Acute Respiratory Distress Syndrome
IN this issue of ANESTHESIOLOGY, Thille and an international group of coworkers recognized for their expertise in acute respiratory distress syndrome (ARDS) bring convincing evidence that positive end-expiratory pressure– induced alveolar recruitment does not differ between patients with pulmonary and extrapulmonary ARDS. The authors recommend that the origin of ARDS should not influence select...
متن کاملResponse to recruitment maneuver influences net alveolar fluid clearance in acute respiratory distress syndrome.
BACKGROUND Alveolar fluid clearance is impaired in the majority of patients with acute respiratory distress syndrome (ARDS). Experimental studies have shown that a reduction of tidal volume increases alveolar fluid clearance. This study was aimed at assessing the impact of the response to a recruitment maneuver (RM) on net alveolar fluid clearance. METHODS In 15 patients with ARDS, pulmonary ...
متن کاملEffects of positive end-expiratory pressure on gastric mucosal perfusion in acute respiratory distress syndrome
INTRODUCTION Positive end-expiratory pressure (PEEP) improves oxygenation and can prevent ventilator-induced lung injury in patients with acute respiratory distress syndrome (ARDS). Nevertheless, PEEP can also induce detrimental effects by its influence on the cardiovascular system. The purpose of this study was to assess the effects of PEEP on gastric mucosal perfusion while applying a protect...
متن کاملHypersensitivity Reaction and Acute Respiratory Distress Syndrome in Pyrethroid Poisoning and Role of Steroid Therapy
Background: Pyrethroids are generally of low toxicity to humans, but in suicidal poisonings which are usually associated with ingestion of high doses, they lead to severe systemic effects. Case Report: A 30-year old woman presented to emergency department with a history of intentional ingestion of about 15 mL of prallethrin around 3 days earlier. She complained of shortness of breath along with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Critical Care
دوره 10 شماره
صفحات -
تاریخ انتشار 2006