Leakage current of hadron irradiated silicon detectors - material dependence
نویسندگان
چکیده
The leakage current increase of silicon detectors irradiated with fast neutrons was measured in the fluence range from 10 to 10 cm for a wide range of different starting material. The oxygen concentration in the investigated silicon varied from 9×10 cm to below 2×10 cm and the carbon concentration from 2×10 cm to below 5×10 cm. Furthermore the resistivity differed from 100 Ωcm to 20 KΩcm for the used n-type and from 400 Ωcm to 2 KΩcm for the p-type silicon. It is found that up to the highest fluence the current related damage parameter alpha is almost independent of the initial resistivity and impurity concentration. After irradiation a universal annealing behavior for all material is observed which unmistakably indicates that the microscopic defects underlying the generation of leakage current are of intrinsic origin. Furthermore it is shown that the parameterization of the annealing behavior at an elevated temperature (here 60°C) provides an excellent tool for comparing the so-called hardness factors of different irradiation sources. As an example the hardness factors for the 24 GeV/c CERN Proton Synchrotron and the TRIGA research reactor in Ljubljana were determined to be 0.51 and 0.76 respectively.
منابع مشابه
Charge Collection and Capacitance-Voltage analysis in irradiated n-type magnetic Czochralski silicon detectors
The depletion depth of irradiated n-type silicon microstrip detectors can be inferred from both the reciprocal capacitance and from the amount of collected charge. Capacitance-voltage (C-V) measurements at different frequencies and temperatures are being compared with the bias voltage dependence of the charge collection on an irradiated n-type magnetic Czochralski silicon detector. Good agreeme...
متن کاملRadiation Damage Studies of Silicon Microstrip Sensors
Various types of large area silicon microstrip detectors were fabricated for development of radiation-tolerant detectors operational in the LHC ATLAS SCT. The detectors were irradiated with 12-GeV protons at KEK to fluences of 1.7×10 and 4.2×10 protons/cm. Irradiated samples include n-on-n detectors with 4 kΩ cm bulk resistivity and p-on-n detectors with 1 kΩ cm and 4 kΩ cm bulk resistivities. ...
متن کاملCharacterisation of p-in-n ATLAS silicon microstrip detectors fabricated by Hamamatsu Photonics and irradiated with 24GeV/c protons to 3 × 1014pcm−2
P-in-n silicon microstrip prototype detectors for the ATLAS experiment at CERN have been designed and manufactured by Hamamatsu Photonics. Detectors were irradiated at the CERN Proton Synchrotron facility to a fluence of 3× 1014 pcm−2, corresponding to the total fluence anticipated after ten years of operation in the ATLAS semiconductor tracker. They were subsequently annealed for 7 days at 25o...
متن کاملCapacitance-Voltage analysis at different temperatures in heavily irradiated silicon detectors
The main operational parameter of a silicon detector is the charge collected at the electrodes when a particle is impinging on the device. The collected charge should reach its maximum when the detector is fully depleted. Thus it is of major importance to determine the full depletion voltage of the detector before and after irradiation with fast hadron fluence (Φ ). The measurement of the full ...
متن کاملEUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN-PPE/97-11 4 February 1997 BULK DAMAGE EFFECTS IN IRRADIATED SILICON DETECTORS DUE TO CLUSTERED DIVACANCIES
High resistivity silicon particle detectors will be used extensively in experiments at the future CERN Large Hadron Collider where the enormous particle fluences give rise to significant atomic displacement damage. A model has been developed to estimate the evolution of defect concentrations during irradiation and their electrical behaviour according to Shockley-Read-Hall (SRH) semiconductor st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999