Blink frequency and duration during perimetry and their relationship to test-retest threshold variability.

نویسندگان

  • Yanfang Wang
  • Sonia S Toor
  • Ramesh Gautam
  • David B Henson
چکیده

PURPOSE To describe different patterns of blinking in patients undergoing a visual field test and to establish whether the blink parameters are related to threshold variability. METHODS Thirty-nine patients with diagnosed or suspected glaucoma were recruited to undertake a perimetric task twice. Blinks were detected with a video eye-tracker system that records at a sampling rate of 60 Hz. Blink frequency, duration, and episodes of microsleep (eye closures >500 ms) were analyzed, and correlated with test-retest threshold variability. The timing of blinks with respect to stimulus presentation was analyzed and the percentage of seen stimuli for all presentations (POS(overall)) and those overlapped with blinks (POS(overlapped)) were compared. RESULTS Blink frequency ranged from 0 to 58 per minute. A significant increase in blink frequency was observed in the second test (P < 0.001), whereas blink duration and microsleep episodes were not significantly different between the two tests. The relationship between test-retest threshold variability and all blink parameters was not significant. For suprathreshold stimulus presentations, blinks often occurred after presentation, whereas for subthreshold presentations, their timing was independent of stimulus timing. The difference between POS(overall) and POS(overlapped) was significant (P < 0.001), and a slight decrease in POS(overlapped) was observed with the increase of overlap duration. CONCLUSIONS A wide range of blink frequencies was observed during perimetric testing. Although no blink parameters showed significant influence on threshold variability, when the blinks overlapped with a stimulus presentation, the probability of seeing was reduced. For suprathreshold stimuli, blinks often occurred after the presentation, whereas for subthreshold presentations, there was no relationship to presentation time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.

PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perime...

متن کامل

Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.

PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...

متن کامل

Test-retest variability of multifocal visual evoked potential and SITA standard perimetry in glaucoma.

PURPOSE To investigate the test-retest variability of multifocal visual evoked potential (mfVEP) and threshold perimetry in glaucoma, and to examine the relationship between the two techniques. METHODS Data were recorded using the AccuMap mfVEP and SITA standard program of the Humphrey Field Analyzer. Data were obtained twice within a 4-week period from both eyes of 74 patients with varying a...

متن کامل

Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension.

AIM To evaluate the learning effect of Frequency Doubling Technology (FDT) perimetry using the Humphrey Matrix-FDT perimetry (Matrix) 24-2 full-threshold program on patients with ocular hypertension experienced with standard automated perimetry. METHODS Twenty-four patients with ocular hypertension underwent 5 full-threshold Matrix tests at intervals of 5+/-2 days. Learning effect was defined...

متن کامل

Modeling the sensitivity to variability relationship in perimetry

PURPOSE Studies in glaucoma patients show that standard automated perimetry results increase in variability as sensitivity decreases. However, the reasons for this change are unclear. This study presents the principle of Divergent Dysfunction as a possible explanation for this change in variability, and incorporates it into a model that can be used to simulate perimetry. METHODS A computer pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 7  شماره 

صفحات  -

تاریخ انتشار 2011