Determination of Chlamydia trachomatis prevalence in an asymptomatic screening population: performances of the LCx and COBAS Amplicor tests with urine specimens.
نویسندگان
چکیده
This study determined the performances of the LCx (Abbott) and COBAS Amplicor (Roche) tests with urine specimens for the detection of Chlamydia trachomatis in an asymptomatic screening population. Randomly selected women and men (age range, 15 to 40 years) registered in 20 general practices in Amsterdam, The Netherlands, were invited to participate in this study. Urine specimens (n = 2, 906; 1,138 specimens from men and 1,717 specimens from women) were tested for C. trachomatis by the COBAS Amplicor (Roche) and LCx (Abbott) tests. Samples which were positive by only one assay were subjected to discrepant analyses by a third assay (in-house plasmid PCR). By the LCx assay C. trachomatis DNA was detected in urine specimens from 46 of 1,717 women and 29 of 1,138 men, while the COBAS Amplicor detected C. trachomatis DNA in 52 and 35 specimens, respectively. When comparing the LCx and COBAS Amplicor tests, 32 test results (20 for women and 12 for men) were discrepant. After discrepant analyses the following sensitivities, specificities, and positive predictive values were found for the LCx and COBAS Amplicor tests: 78.6 versus 98.8%, 99.7 versus 99.9%, and 88.0 versus 95.4%, respectively. No prominent differences were found between men and women with regard to the test performances. After discrepant analyses the overall prevalences of C. trachomatis in women and men were 3.0 and 2.8%, respectively. For both women and men the prevalence in the younger age groups was higher than that in the older age groups. In conclusion, the COBAS Amplicor tests shows better diagnostic characteristics than the LCx assay for the detection of C. trachomatis in urine specimens from an asymptomatic screening population. In this asymptomatic population the overall prevalence of C. trachomatis was 2.9%.
منابع مشابه
Comparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملComparison of three commercially available amplification assays, AMP CT, LCx, and COBAS AMPLICOR, for detection of Chlamydia trachomatis in first-void urine.
We compared the Gen-Probe transcription-mediated amplification assay (AMP CT), the Abbott LCx assay, and the Roche COBAS AMPLICOR assay for the detection of Chlamydia trachomatis in a mixed population in urine samples. First-void urine, urethral specimens, and cervical specimens in females were obtained from 1,000 patients (544 males and 456 females) visiting the outpatient sexually transmitted...
متن کاملComparison of performances of two commercially available tests, a PCR assay and a ligase chain reaction test, in detection of urogenital Chlamydia trachomatis infection.
The diagnostic performance of a PCR test (Roche Cobas Amplicor CT/NG Test) and that of a ligase chain reaction (LCR) test (Abbott LCx Chlamydia trachomatis assay) were compared by using endocervical and urethral swab specimen culture as a reference test. First-void urine (FVU) and endocervical and urethral swab specimens were collected from 1,015 unselected patients attending a sexually transmi...
متن کاملMulticenter evaluation of the AMPLICOR and automated COBAS AMPLICOR CT/NG tests for detection of Chlamydia trachomatis.
The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-n...
متن کاملUse of pooled urine samples and automated DNA isolation to achieve improved sensitivity and cost-effectiveness of large-scale testing for Chlamydia trachomatis in pregnant women.
The success of large-scale screening for Chlamydia trachomatis depends on the availability of noninvasive samples, low costs, and high-quality testing. To evaluate C. trachomatis testing with pregnant women, first-void urine specimens from 750 consecutive asymptomatic pregnant women from the Rotterdam area (The Netherlands) were collected. Initially, we investigated the performance of three dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 37 10 شماره
صفحات -