Determination of natural and depleted uranium in urine at the ppt level: an interlaboratory analytical exercise.
نویسندگان
چکیده
An analytical exercise was initiated in order to determine those procedures with the capability to measure total uranium and uranium (238U/235U) isotopic ratios in urine samples containing >0.02 microg U kg-1 urine. A host laboratory prepared six identical sets of twelve synthetic urine samples containing total uranium in the range of 25 to 770 ng U kg-1 urine and with 238U/235U isotopic ratios ranging from 138 (100% NU) to 215 (51% DU). Sets of samples were shipped to five testing laboratories (four based in Canada and one based in Europe). Each laboratory utilized one of the following analytical techniques: sector field inductively coupled plasma mass spectrometry (ICP-SF-MS), quadrupole inductively coupled plasma mass spectrometry (ICP-Q-MS), thermal ionization mass spectrometry (TIMS), and instrumental/delayed neutron activation analysis (I/DNAA), in their analyses.
منابع مشابه
Determination of uranium isotopes (234U, 238U) and natural uranium (U-nat) in water samples by alpha spectrometry
Background: Due to the potential public health effects of releases of uranium to the environment, isotopic determination and measurement of this radionuclide in environmental samples is very important. Achieving this goal, monitoring programs for this radionuclide seems necessary to be applied in many countries. Materials and Methods: The uranium was separated from the water samples using anion...
متن کاملUranium in Urine: Quantification and Isotope Ratio Determination
While the quantification of uranium is therefore demanding in the diluted sample, uranium isotope ratio determination requires the ultimate in instrumental performance as good precisions for large isotope ratios are required at low concentrations. The abundances of the three naturally occurring U isotopes are shown in Table 1, together with the 234U/238U and 235U/238U ratios. The nuclear indust...
متن کاملUranium in Urine: Quantification and Isotope Ratio Determination
The second point makes the matrix matching of standards to samples for direct analysis impossible and, in order to normalize all samples to a similar matrix, the analysis of a diluted (or digested) solution is preferable. High instrumental sensitivity is then required to reliably measure the resulting single digit pg g-1 uranium concentrations. While the quantification of uranium is therefore d...
متن کاملFree Radical Scavenging Activity of Silymarin with Refrence to Depleted Uranium Induced Mitochondrial Dysfunction
Introduction: Recently depleted uranium is being widely used as anti-armour ammunition and at very high temperature, results in information of an aerosol of very small uranium oxide particles, which may be inhaled. It is alleged that these particles represent a new battlefield hazard because of the chemical toxicology and/or radioactivity. Method & materials: Male Wistar strain albino rats ...
متن کاملBiological Monitoring for Depleted Uranium Exposure in U.S. Veterans
BACKGROUND As part of an ongoing medical surveillance program for U.S. veterans exposed to depleted uranium (DU), biological monitoring of urine uranium (U) concentrations is offered to any veteran of the Gulf War and those serving in more recent conflicts (post-Gulf War veterans). OBJECTIVES Since a previous report of surveillance findings in 2004, an improved methodology for determination o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Health physics
دوره 90 5 شماره
صفحات -