Response to henderson et Al. "Prevention of mechanical failures in implanted spinal cord stimulation systems".

نویسنده

  • Y Eugene Mironer
چکیده

Introduction.  Spinal cord stimulation (SCS) is an effective procedure for the treatment of neuropathic extremity pain, with success rates approaching 70%. However, mechanical failures, including breakage and migration, can significantly limit the long-term effectiveness of SCS. A systematic analysis of surgical techniques was undertaken by a consensus group, coupled with extensive in vivo and in vitro biomechanical testing of system components. Methods.  A computer model based on morphometric data was used to predict movement in a standard SCS system between an anchored lead and pulse generator placed in various locations. These displacements were then used to determine a realistic range of forces exerted on components of the SCS system. Laboratory fixtures were constructed to subject leads and anchors to repetitive stresses until failure occurred. An in vivo sheep model also was used to determine system compliances and failure thresholds in a biologically realistic setting. A panel of experienced implanters then interpreted the results and related them to clinical observations. Results.  Use of a soft silastic anchor pushed through the fascia to provide a larger bend radius for the lead was associated with a time to failure 65 times longer than an anchored but unsupported lead. In addition, failures of surgical paddle leads occurred when used with an anchor, whereas without an anchor, no failures occurred to 1 million cycles. Based on these findings, the panel recommended a paramedian approach, abdominal pulse generator placement, maximizing bend radius by pushing the anchor through the fascia, and anchoring of the extension connector near the lead anchor. Discussion.  Several factors are important in longevity of SCS systems. We discovered that technical factors can make a large difference in SCS reliability and that strict attention to these "best practices" will provide the best chance for maintaining the integrity of SCS systems over the long term.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spontaneous Lead Breakage in Implanted Spinal Cord Stimulation Systems

Spinal cord stimulation (SCS) has become an established clinical option for treatment of refractory chronic pain. Current hardware and implantation techniques for SCS are already highly developed and continuously improving; however, equipment failures over the course of long-term treatment are still encountered in a relatively high proportion of the cases treated with it. Percutaneous SCS leads...

متن کامل

Compound Action Potential of Isolated Spinal Cord: A Biophysical Analysis to Address Activity of Individual Fibers Following Contusion Injury

Compound action potential (CAP) of spinal cord represents valuable properties of neural fibers including excitability, rate of myelination and membrane integrity. These properties are measured using amplitude, latency and area under curve of CAPs recorded from spinal cord. Here, the isolated spinal cord was set in a double sucrose gap (DSG) chamber and its response to intracellular stimulation ...

متن کامل

Restoring Motor Functions in Paralyzed Limbs through Intraspinal Multielectrode Microstimulation Using Fuzzy Logic Control and Lag Compensator

In this paper, a control strategy is proposed for control of ankle movement on animals using intraspinal microstimulation (ISMS). The proposed method is based on fuzzy logic control. Fuzzy logic control is a methodology of intelligent control that mimics human decision-making process. This type of control method can be very useful for the complex uncertain systems that their mathematical model ...

متن کامل

Chronic intrathecal cannulation enhances nociceptive responses in rats.

The influence of a chronically implanted spinal cannula on the nociceptive response induced by mechanical, chemical or thermal stimuli was evaluated. The hyperalgesia in response to mechanical stimulation induced by carrageenin or prostaglandin E2 (PGE2) was significantly increased in cannulated (Cn) rats, compared with naive (Nv) or sham-operated (Sh) rats. Only Cn animals presented an enhance...

متن کامل

Spinal cord stimulation: does frequency matter?

243 August 2013 S PINAL cord stimulation was first described in 1967 in an intriguing case report provided by Shealy et al.1 This first case involved the relief from cancerrelated pain using a surgically implanted electrode sutured to the dura to provide stimulation of the dorsal columns. Although the entire treatment was only for approximately 1 day before the patient’s demise, stimulation usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Neurosurgery

دوره 57 2  شماره 

صفحات  -