Scatter and attenuation correction for brain SPECT using attenuation distributions inferred from a head atlas.
نویسندگان
چکیده
UNLABELLED Sequential transmission scanning (TS)/SPECT is impractical for neurologically impaired patients who are unable to keep their heads motionless for the extended duration of the combined scans. To provide an alternative to TS, we have developed a method of inferring-attenuation distributions (IADs), from SPECT data, using a head atlas and a registration program. The validity of replacing TS with IAD was tested in 10 patients with mild dementia. METHODS TS was conducted with each patient using a collimated 99mTc line source and fanbeam collimator; this was followed by hexamethyl propyleneamine oxime-SPECT. IAD was derived by deformably registering the brain component of a digital head atlas to a preliminary SPECT reconstruction and then applying the resulting spatial transformation to the full head atlas. SPECT data were reconstructed with scatter and attenuation correction. Relative regional cerebral blood flow was quantified in 12 threshold-guided anatomic regions of interest, with cerebellar normalization. SPECT reconstructions using IAD were compared with those using TS (which is the "gold standard") in terms of these regions of interest. RESULTS When we compared all regions of interest across the population, the correlation between IAD-guided and TS-guided SPECT scans was 0.92 (P < 0.0001), whereas the mean absolute difference between the scans was 7.5%. On average, IAD resulted in slight underestimation of relative regional cerebral blood flow; however, this underestimation was statistically significant for only the left frontal and left central sulcus regions (P = 0.001 and 0.002, respectively). Error analysis indicated that approximately 10.0% of the total error was caused by IAD scatter correction, 36.6% was caused by IAD attenuation correction, 27.0% was caused by discrepancies in region-of-interest demarcation from quantitative errors in IAD-guided reconstructions, and 26.5% was caused by patient motion throughout the imaging procedure. CONCLUSION SPECT reconstructions guided by IAD are sufficiently accurate to identify regional cerebral blood flow deficits of 10%, which are typical in moderate and advanced dementia.
منابع مشابه
Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)
Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...
متن کاملA New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images
Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 41 9 شماره
صفحات -
تاریخ انتشار 2000