Real world utilization and impact of the wearable cardioverter-defibrillator in a community setting

نویسندگان

  • Aditi Naniwadekar
  • Talal Alnabelsi
  • Kamal Joshi
  • Edinrin Obasare
  • Allan Greenspan
  • Sumeet Mainigi
چکیده

INTRODUCTION The wearable cardioverter-defibrillator (WCD) is used in patients at risk for sudden cardiac death (SCD) but not immediate candidates for intracardiac defibrillator (ICD) implantation. METHODS We performed a single center retrospective study of patients prescribed WCD upon hospital discharge from January 2002 to October 2015. Clinical characteristics were obtained from the hospital electronic database and device data from Zoll LifeVest database. RESULTS Of 140 patients, 62% were men, 85.9% were African-American and mean age was 58.2 ± 15.5 years. Ischemic cardiomyopathy was present in 45 (32%) and non-ischemic cardiomyopathy in 64 patients (46%). Mean left ventricular ejection fraction (EF) was 0.28 ± 0.4. WCD was worn for 7657 patient-days (21 patient-years), with each patient using WCD for median of 43 days (IQR: 7-83 days), and daily mean use 17.3 ± 7.5 h. There were a total of 6 (4.2%) WCD shocks of which 2 (1.4%) were appropriate (one for VT, one for VF) and 4 (2.8%) were inappropriate (2 had supraventricular tachycardia, 2 had artifact). Two patients who received appropriate shocks were African-American with non-ischemic cardiomyopathy (EF<20%), non-sustained VT and wide QRS duration. Upon termination of WCD use, 45 (32%) received ICD while EF improved in 34 patients (32%). CONCLUSIONS In a predominantly minority, community setting, WCD compliance is high and use is effective in aborting SCD. However, inappropriate shocks do occur. A significant proportion of patients did not ultimately require ICD implantation suggesting this may be a cost-effective strategy in patients at risk of SCD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Management of sudden cardiac death in cardiac sarcoidosis using the wearable cardioverter defibrillator

BACKGROUND Patients with cardiac sarcoidosis are at increased risk of ventricular tachycardia/fibrillation. OBJECTIVE We tested the hypothesis that the wearable cardioverter defibrillator can be used to mitigate the risk of sudden cardiac death among cardiac sarcoidosis patients. METHODS A retrospective review of the commercial database identified cardiac sarcoidosis patients who wore the w...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

First experience with the wearable cardioverter defibrillator in the Netherlands

The implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with an increased risk of sudden cardiac death (SCD). The wearable cardioverter defibrillator (WCD) is an alternative to the ICD in patients with a transient ICD indication or those in whom an ICD temporarily cannot be implanted. We describe here the technical details of the WCD and report three pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017