Do changes in relative blood volume monitoring correlate to hemodialysis-associated hypotension?

نویسندگان

  • John Booth
  • Jennifer Pinney
  • Andrew Davenport
چکیده

INTRODUCTION Intradialytic hypotension remains the most common complication for outpatient hemodialysis, and relative blood volume monitoring was designed to reduce hypotension. Reports of the usefulness of this technology, however, have been variable. METHODS We audited the usefulness of relative blood volume monitoring recorded throughout the mid-week dialysis in 72 stable adult outpatients who had multifrequency bioimpedance measurements. RESULTS The blood volume measurement (BVM) at the end of the session was 91.6 ± 0.6% and was not different from the nadir BVM recorded (90.7 ± 0.5). The BVM was strongly correlated with change in hematocrit (r = -0.56, p < 0.001) and albumin (r = -0.69, p < 0.001), but had no relationship with pre-, intra- or postdialysis blood pressure recordings. The BVM was not associated with ultrafiltration volume, but did correlate with a postdialysis change in extracellular fluid volume (r = -0.39, p = 0.006). CONCLUSION In this audit, although the BVM at the end of the dialysis session was correlated with changes in hematocrit, serum albumin and extracellular fluid volume, the change in the relative BVM did not mirror changes in intradialytic blood pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Absolute blood volume in hemodialysis patients: why is it relevant, and how to measure it?.

Intradialytic hypotension (IDH) is the most common complication during hemodialysis and is associated with significant morbidity. It occurs as a consequence of a reduction in blood volume during ultrafiltration. Today, devices for monitoring relative blood volume (i.e. the intradialytic blood volume as a fraction of the blood volume at the start of the dialysis treatment) are routinely availabl...

متن کامل

Critical evaluation of blood volume measurements during hemodialysis.

Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hyd...

متن کامل

Predicting episodes of hypotension by continuous blood volume monitoring among critically ill patients in acute renal failure on intermittent hemodialysis.

BACKGROUND Acute renal failure (ARF) develops in 23% of all critically ill patients. Hypotension occurs in 25% to 50% of patients during intermittent hemodialysis (IHD) for ARF. Blood volume (BV) monitoring has been used in chronic renal failure, with limited use in ARF during IHD. Continuous BV monitoring in the stable critically ill patient with ARF could predict, and possibly prevent, develo...

متن کامل

Design and Construct an Optical Device to Determine Relative Blood Volume in Patients Undergoing Hemodialysis

BACKGROUND Occurrence of hypotension during hemodialysis in nearly 20-30% of patients, shows is the necessity of continuous monitoring the patients' blood pressure during hemodialysis. Since directly and non-invasively continuous blood pressure monitoring, is not easy, finding a parameter related to blood pressure, for indirect monitoring is of great value. Related blood volume (RBV) is one of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephron. Clinical practice

دوره 117 3  شماره 

صفحات  -

تاریخ انتشار 2011