Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations

نویسندگان

  • Juraj Artner
  • Balkan Cakir
  • Heiko Reichel
  • Friederike Lattig
چکیده

BACKGROUND The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique. OBJECTIVE To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections. STUDY DESIGN Comparative study with technical considerations. METHODS A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann-Whitney U-Test. Technical details and anatomical considerations were provided. RESULTS A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy- guidance levels. CONCLUSION Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations

Despite the good general patient acceptance, high patient comfort, safety and precision in the needle placement, exposure to radiation in computed tomography (CT)-guided spinal interventions remains a serious concern, and is often used to argue against its use. The aim of this study was to determine the technical possibilities of reducing the radiation dose in CT-guided epidural and periradicul...

متن کامل

A new technical contribution for ultrasound-guided injections of sacro-iliac joints.

INTRODUCTION Sacroiliac joint (SIJ) represents a difficult location for local therapies, as intra-articular injections may be hard to execute, especially in particular conditions such as chronic inflammatory diseases. However, in selected patients, local therapies may be considered. Some recent studies demonstrated the feasibility of ultrasound (US)-guided injection of SIJ, but still a complete...

متن کامل

Ultrasound-guided versus Computed Tomography-controlled facet joint injections in the middle and lower cervical spine: a prospective randomized clinical trial.

OBJECTIVES A prospective randomized clinical trial was conducted to evaluate accuracy, time-saving, radiation doses and pain relief of ultrasound-guided (US) facet joint injections versus Computed Tomography (CT)-controlled interventions in the cervical spine. MATERIAL AND METHODS Forty adult patients were consecutively enrolled and randomly assigned to the US- or CT group. US-guided facet jo...

متن کامل

CT fluoroscopy-guided cervical interlaminar steroid injections: safety, technique, and radiation dose parameters.

BACKGROUND AND PURPOSE Cervical epidural steroid injections are approached with trepidation because of concerns over safety, including direct spinal cord injury. CT fluoroscopy is an alternative to conventional fluoroscopy that could potentially help reduce the risk of injury by providing improved localization of the needle tip. We sought to determine rates of technical success and risk of comp...

متن کامل

Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study

  Background: Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient’s quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations.   Methods: Between January 2006 and December 2014, 14 patients with sacroi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2012