Microfluidic perfusion system for culturing and imaging yeast cell microarrays and rapidly exchanging media.
نویسندگان
چکیده
High resolution live cell microscopy is increasingly used to detect cellular dynamics in response to drugs and chemicals, but it depends on complex and expensive liquid handling devices that have limited its wider adoption. Here, we present a microfluidic perfusion system that is built without using specialized microfabrication infrastructure, simple to use because only a pipette is needed for liquid handling, and yet allows for rapid media exchange and simultaneous fluorescence microscopy imaging. Yeast cells may be introduced from a culture, or spotted as arrays on a coverslip, and are sandwiched with a 20 mum thick track-etched membrane. A second coverslip and a mesh with 120 mum porosity are placed on top, forming a microfluidic conduit for lateral flow of solutions by capillary effects. Solutions introduced through the inlet flow through the mesh and chemicals diffuse vertically across the membrane to the cells trapped below. Solutions are exchanged by adding a new sample to the inlet. Using this system, we studied the dynamic response of F-actin in living yeast expressing Sac6-EGFP-a protein associated with discrete F-actin structures called "patches"-to the drug latrunculin A, a well known inhibitor of actin polymerization. We observed that the patches disappeared in 85% of the cells within 5 min, and re-assembled in 45 min following exchange of the drug with media. The perfusion system presented here is a simple, inexpensive device suited for analysis of drug dose-response and regeneration of single cells and arrays of cells.
منابع مشابه
طراحی و ساخت سیستم میکروفلوییدی و ارزیابی قابلیت آن جهت تولید اینترلوکین 2 توسط سلول های جورکت
Background and purpose: Microfluidic systems are microstructures that could be used to improve the conventional cell culture protocols used in laboratories. The aim of this research was to design and construct the microfluidic system and evaluating its ability to produce IL-2 by jurkat cells. Material and methods: At first, the sketch of microfluidic canals was designed by Corel draw and wa...
متن کاملCulturing Adult Rat Hippocampal Neurons with Long-Interval Changing Media
Background: Primary cultures of embryonic neurons have been used to introduce a model of neurons in physiological and pathological conditions. However, age-related cellular events limit this method as an optimal model in adult neurodegenerative diseases studies. Besides, short-interval changing media in previous cultures decreases the effectiveness of this model. As an example of this matter, w...
متن کاملNanoporous membrane-sealed microfluidic devices for improved cell viability.
Cell-laden microfluidic devices have broad potential in various biomedical applications, including tissue engineering and drug discovery. However, multiple difficulties encountered while culturing cells within devices affecting cell viability, proliferation, and behavior has complicated their use. While active perfusion systems have been used to overcome the diffusive limitations associated wit...
متن کاملبررسی فراوانی اونیکومایکوزیس ناشی از قارچ های مخمری در ناخن های دیستروفیک بیماران مراجعه کننده به بیمارستان رازی 90-1389
Background: Yeasts are one of the most common causes of onychomycosis. In countries like Iran, Saudi Arabia, Italia and Spain, yeasts are reported as the most frequent causes of onychomycosis. Inhibition of the immune system such as chemotherapy, radiation therapy, the use of broad spectrum antibodies, aggressive treatment with corticosteroids, HIV and diabetes melitus predispose the body wit...
متن کاملAn adaptable stage perfusion incubator for the controlled cultivation of C2C12 myoblasts.
Here we present a stage perfusion incubation system that allows for the cultivation of mammalian cells within PDMS microfluidic devices for long-term microscopic examination and analysis. The custom-built stage perfusion incubator is adaptable to any x-y microscope stage and is enabled for temperature, gas and humidity control as well as equipped with chip and tubing holder. The applied double-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Lab on a chip
دوره 10 18 شماره
صفحات -
تاریخ انتشار 2010