Lung biopsy with the high speed drill in a developing country.

نویسنده

  • B Teklu
چکیده

The results of high speed air drill lung biopsy during 38 months in Addis Ababa is reported. Even though the diagnostic yield was only 49%, trephine lung biopsy has a place in the investigation of diffuse and accessible localised lesions of the lung. It has proved to be a relatively safe and simple procedure. Nineteen male and 20 female patients were studied and in addition eight postmortem specimens of lung tissue were included. The chest radiograph showed diffuse pulmonary infiltrates in 42 and localised in six, with diagnostic biopsy specimens in 20 and five respectively. Biopsy of the inferior lung in the lateral decubitus position in patients with diffuse lung lesions has yielded larger specimens than has routine biopsy performed in the sitting position. Since the only patient who developed appreciable haemoptysis was the single patient with chronic cor pulmonale, caution should be exercised in such cases. A chest radiograph is indicated after biopsy only when the clinical condition of the patient warrants it.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thorax 1987;42:858-862 Drill biopsy in the diagnosis of lung lesions

A high speed pneumatic drill was used to perform 190 percutaneous transthoracic biopsies in 161 patients. The resultant cores of tissue provided a definite diagnosis in 146 patients, giving a success rate of 90 7%. Complications occurred in 58 patients, subcutaneous emphysema being the most common, though only seven patients required active treatment, giving a rate of 3-7% for important complic...

متن کامل

A new instrument and technique for lung biopsy using local anaesthesia.

The problem of crossing the pleural cavity to obtain a specimen of lung for examination without at the same time leaving a pneumothorax or causing haemorrhage has hindered the investigation of diffuse lung disease. The various techniques used have been a formal, though limited, thoracotomy, needle biopsy, and, more recently, high-speed air-drill biopsy. Each of these techniques has complication...

متن کامل

Percutaneous trephine biopsy of the lung.

Needle lung biopsy performed with a trephine cutting needle attached to a high speed pneumatic drill is a new technique which can be expected to yield a high quality lung specimen in 85 percent 90 percent of attempts. This technique is especially applicable to diffuse pulmonary disease. The most frequent complication is the development of pneumothorax (in up to 65 percent of biopsies) which if ...

متن کامل

Drill biopsy in the diagnosis of lung lesions.

A high speed pneumatic drill was used to perform 190 percutaneous transthoracic biopsies in 161 patients. The resultant cores of tissue provided a definite diagnosis in 146 patients, giving a success rate of 90.7%. Complications occurred in 58 patients, subcutaneous emphysema being the most common, though only seven patients required active treatment, giving a rate of 3.7% for important complic...

متن کامل

THE DIAGNOSTIC YIELD OF TRANSBRONCHIAL LUNG BIOPSY IN DIFFUSE INFILTRATIVE PULMONARY DISEASES BY PLAIN CUP FORCEPS. A STUDY OF 54 CASES IN IRAN

The technique of transbronchial lung biopsy (TBLB) has expanded the diagnostic yield of bronchoscopy . In this article we are presenting 54 patients with diffuse pulmonary parenchymal involvement who underwent this procedure during six years between June 1980 and December 1989. The diagnostic yield of this technique in diffuse pulmonary parenchymal disease is great and was 66 percent exclu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 41 10  شماره 

صفحات  -

تاریخ انتشار 1986