False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.

نویسندگان

  • C R Peter
  • M A Thompson
  • D L Wilson
چکیده

Sera from 628 nonsyphilitic individuals were tested with the Rapid Plasma Reagin-Card, Fluorescent Treponemal Antibody-Absorbed, and Hemagglutination Treponemal Test for Syphilis tests to ascertain the comparative specificity of these tests. Many sera were also tested with the quantitative Venereal Disease Research Laboratory test. Sera included in the study were from both normal individuals and patients with a variety of illnesses and conditions. The Hemagglutination Treponemal Test for Syphilis gave the lowest overall percentage of false-positive reactions (1.6%), followed by the Fluorescent Treponemal Antibody-Absorbed test (3.3%) and the Rapid Plasma Reagin-Card test (10.8%).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Syphilis serology in human immunodeficiency virus infection: evidence for false-negative fluorescent treponemal testing.

Injection drug users were assessed serologically for human immunodeficiency virus infection and syphilis every 6 months. Treatment histories were reviewed for any high-titer biologic false-positive (BFP) reactors, that is, persons with rapid plasma reagin (RPR) titers > or = 1:4 and negative results for fluorescent treponemal antibody absorption (FTA-ABS) tests. Selected sera were analyzed furt...

متن کامل

Reactivity of microhemagglutination, fluorescent treponemal antibody absorption, Venereal Disease Research Laboratory, and rapid plasma reagin tests in primary syphilis.

Seroreactivity of sera from 109 patients with first-infection primary syphilis was 98.2% in the fluorescent treponemal antibody absorption test, 92.7% in the rapid plasma reagin 18-mm circle card test, 72.5% in the microhemagglutination test (MHA-TP), and 72.5% in the Venereal Disease Research Laboratory test. Seroreactivity of sera from 18 patients with primary syphilis with documented previou...

متن کامل

Evaluation of reagin screen, a new serological test for syphilis.

A total of 1,020 serum and plasma specimens were tested using the Venereal Disease Research Laboratory (VDRL), Rapid Plasma Reagin (RPR) card, Reagin Screen (RST) and Fluorescent Treponemal Antibody-Absorption (FTA-ABS) tests. In 257 normal patients, all screening tests were nonreactive; the FTA-ABS test was reactive for one patient. In 588 patients with treated and untreated syphilis, the RST ...

متن کامل

Syphilis Serology among HIV-Seroreactive Patients

Sexually transmitted diseases (STD’s), including Syphilis, are associated with an increased risk of Human immunodeficiency virus (HIV) infection. Though Rapid Plasma Reagin test (RPR) is a screening test to diagnose syphilis, a negative RPR may not rule out syphilis in HIV sero-reactive patients. For laboratory confirmation, one specific treponemal test, namely Treponema Pallidum Haemagglutinat...

متن کامل

Rapid plasma reagin (RPR) card test. A screening method for treponemal disease.

The specific FTA-ABS and TPI tests are too costly and time-consuming to be used as screening procedures for treponemal disease. The VDRL test detects reagin, the antibody amongst others produced in syphilis and yaws and also present in a wide variety of disorders giving the biological false positive reaction. The RPR card test (Portnoy, Garson, and Smith, 1957; Reed, 1965), like the VDRL test, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 1979