Validation of collateral fractional flow reserve by myocardial perfusion imaging.
نویسندگان
چکیده
BACKGROUND Collateral fractional flow reserve (FFR(coll)) is an index to quantify collateral blood flow, derived from coronary pressure measurements. Although well defined theoretically, its direct validation by myocardial perfusion imaging has not been established so far. Validating this index by myocardial perfusion imaging is the main aim of this study. METHODS AND RESULTS Twenty-four consecutive patients with stable angina and single left anterior descending artery stenosis underwent simultaneous measurement of aortic pressure (P(a)), coronary wedge pressure (P(w)), and central venous pressure (P(v)) during balloon inflation. FFR(coll) was calculated and compared with the extent and severity of the defect during coronary occlusion using (99m)Tc-sestamibi imaging at balloon inflation of the respective coronary artery. Although the pressure-derived collateral indexes (P(w), P(w)/P(a), and FFR(coll)) ranged widely, they were closely correlated with extent and severity scores of the nuclear occlusion images and superior to the ECG for that purpose. Of all parameters, FFR(coll) correlated best with the severity score at imaging (r=-0.88), followed by the P(w)/P(a) ratio (r=-0.74) or P(w) alone (r=-0.69). CONCLUSIONS FFR(coll), calculated from coronary pressure during balloon occlusion, is highly correlated with the extent and severity of the defect at myocardial perfusion of the territory of the occluded artery and can be used for quantitative assessment of collateral blood flow in conscious humans.
منابع مشابه
Blood oxygen level dependent and adenosine-perfusion imaging correlates to invasive measurement of fractional flow reserve
Background It has been shown that blood oxygen level dependent (BOLD) cardiac magnetic resonance imaging (CMR) is able to detect myocardial perfusion differences. However, validation of BOLD CMR against myocardial perfusion reserve (MPR) and fractional flow reserve (FFR) is lacking. We sought to analyze the potential diagnostic accuracy of BOLD CMR in comparison to invasively measured FFR which...
متن کاملValidation of dynamic three-dimensional whole heart magnetic resonance myocardial perfusion imaging at 3.0 Tesla against fractional flow reserve for the detection of flow-limiting coronary heart disease
We demonstrate the feasibility of 3D myocardial perfusion CMR at 3 Tesla against fractional flow reserve (FFR) in 53 patients for the detection of flow-limiting coronary artery disease and show good agreement between the techniques. This technique shows excellent diagnostic sensitivity and specificity and may offer an alternative method of detecting ischaemia for the purpose of guiding revascul...
متن کاملAssessment of the collateral circulation of the heart.
Ever since the development of coronary angiography in the early 1960s, the collateral circulation of the heart has fascinated cardiologists and has been the subject of sometimes contradictory and speculative theories. The basis for systematic study of the collateral circulation has been provided by the seminal work of Schaper, who started to perform experimental studies as early as 40 years ago...
متن کامل0054: Validation of stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging against fractional flow reserve for the detection of the extent of ischemia
0430 Table LA Emptying fraction CMR Maximal LAVICMR LGE <17.5% >17.5% p <44 ml/m >44 ml/m p – + p Mitral E/A ratio 2.98±1.82 0.89±0.28 <0.001 1.51±1.4 2.22±1.8 0.2 1.35±1.3 2.43±1.9 0.055 DT TTE (ms) 158±45 217±56 <0.001 190±65 183±53 0.7 219±51 145 ±39 <0.001 Lateral E/e’ 16.9±6.8 12.1±6.4 <0.04 14±7 14.8±7 0.8 13.6±7.4 15.7±6.4 0.4 GLS –10.1±3.1 –17.3±3.7 <0.001 –14.2±5.3 –12.7±4.6 0.4 –16.5±...
متن کاملT2-prepared steady-state free-precession for detection of hemodynamic significance of coronary artery stenosis - a comparison to fractional flow reserve
Background BOLD CMR has been shown to be able to detect myocardial perfusion differences. However, validation of BOLD CMR against FFR is lacking. Aim of our study was to analyze the potential diagnostic accuracy of blood oxygen level-dependent (BOLD) cardiac magnetic resonance imaging (CMR) in comparison to invasively measured fractional flow reserve (FFR) which served as gold standard for a he...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 105 9 شماره
صفحات -
تاریخ انتشار 2002