Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures - a biomechanical in-vitro study

نویسندگان

  • A Paech
  • E Wilde
  • AP Schulz
  • G Heinrichs
  • R Wendlandt
  • C Queitsch
  • B Kienast
  • Ch Jürgens
چکیده

The cut-out of the sliding screw is one of the most common complications in the treatment of intertrochanteric fractures. The reasons for the cut-out are: a suboptimal position of the hip-screw in the femoral head, the type of fracture and poor bone quality. The aim of this study was to reproduce the cut-out event biomechanically and to evaluate the possible prevention of this event by the use of a biopolymer augmentation of the hip screw. Concerning the density and compression force of osteoporotic femoral bone polyurethane foam according to the terms of the Association for Standard Testing Material (ASTMF 1839-97) was used as test material. The polyurethane foam Lumoltan 200 with a compression force of 3.3 Mpa and a density of 0.192 g/cm(3) was used to reproduce the osteoporotic bone of the femoral fragment (density 12 lbm/ft(3)). A cylinder of 50 mm of length and 50 mm of width was produced by a rotary splint raising procedure with planar contact. The axial load of the system was performed by a hydraulic force cylinder of a universal test machine type Zwick 1455, Ulm, Germany. The CCD-angle of the used TGN-System was preset at 130 degrees. The migration pattern of the hip screw in the polyurethane foam was measured and expressed as a curve of the distance in millimeter (mm) against the applied load in Newton (N) up to the cut-out point. During the tests the implants reached a critical changing point from stable to unstable with an increased load progression of steps of 50 Newton. This unstable point was characterized by an increased migration speed in millimeters and higher descending gradient in the migration curve. This peak of the migration curve served as an indicator for the change of the hip screw position in the simulated bone material. The applied load in the non-augmented implant showed that in this group for a density degree of 12 (0,192 g/cm(3)) the mean force at the failure point was 1431 Newton (+/- 52 Newton). In the augmented implant we found that the mean force at the failure point was 1987 Newton (+/- 84 Newton). This difference was statistically significant. In conclusion, the bone density is a significant factor for the stability of the hip screw implant. The osteosynthesis with screws in material with low density increases the chance for cut-out. A biopolymer augmented hip screw could significantly improve the stability of the fixation. The use of augmentation with a fast hardening bone replacement material containing polymer-ceramic changes the point of failure under axial load in the osteoporotic bone model and could significantly improve the failure point. Our study results indicate, that a decrease of failure in terms of cut-out can be achieved with polymer augmentation of hip screws in osteoporotic bones.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study

BACKGROUND Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. AIMS To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of th...

متن کامل

Biomechanical Effects of Cement Augmentation in the Treatment of Intertrochanteric Fractures with Compression Hip Screw Systems in Relation to Osteoporosis of Varying Degrees

Introduction: Screw cut-out and non-union have been cited as major complications with hip screw systems for the treatment of intertrochanteric femoral fractures. Recently, cement augmentation of hip screw system has been introduced to provide better purchase of the screw. However, its effectiveness is not entirely clear when the various degrees of osteoporosis has progressed within the femoral ...

متن کامل

In vitro biomechanical comparison of three methods for internal fixation of femoral neck fractures in dogs.

The in vitro biomechanical properties of three methods for internal fixation of femoral neck fractures were evaluated. Fifty cadaveric femura from Beagle dogs were used. Ten intact femora served as controls. In 40 femura, an osteotomy of the femoral neck was performed to simulate a transverse fracture. With the remaining 30 femura, three repair methods (two medium Orthofix pins, a 2.7 mm cort...

متن کامل

Calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal.

OBJECTIVE To determine the effect of reinforced calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal in a cadaveric model. METHODS The lag screws of dynamic hip screw implants were inserted and subsequently removed in 8 matched pairs of cadaveric, osteoporotic femurs to create a femoral neck defect. One of each pair had the defect augmented ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2010