Dosimetry with a diamond operating as a resistor.

نویسنده

  • E A Burgemeister
چکیده

A very pure diamond with contacts of graphite has a linear current-voltage characteristic when subjected to irradiation. The resistivity is inversely proportional to the dose rate and the sensitivity is extremely high for gamma- and X-rays and electron beams. It is concluded that diamond resistors are suitable for clinical radiation dosimetry. This conclusion is also based on earlier work in which diamonds were used as pinpoint counters.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

متن کامل

بررسی ویژگی‌های شیوه‌های رایج دزیمتری گذشته نگر

As public concern mounts over exposures to ionizing radiation stemming from environmental releases of radionuclides following nuclear accidents, there is a growing need to develop reliable techniques that reconstruct exposures and doses to individuals. Especially in situations where conventional dosimeters were not in place at the time of facing to radiation exposure. In order to provide guidan...

متن کامل

Dosimetric characterization of CVD diamonds in photon, electron and proton beams

Synthetic diamond is potentially one of the more interesting materials in the field of detectors applicable in dosimetry. It is, in fact, tissue equivalent (its atomic number, Z = 6, is very close to the actual atomic number of a biological tissue, Z = 7.5. Moreover it is not toxic and shows a high resistance to radiation damage, a high sensitivity and stability of response, a low leakage curre...

متن کامل

Dosimetric characteristics of active solid state detectors in a 60 MeV proton radiotherapy beam

The solid state active detectors, widely used for conventional radiotherapy, such as diamond detectors (DD) and diodes may be attractive tools also in dosimetry of therapeutic proton beams. Diodes are broadly applied in oncology clinics and routinely used for in-vivo dosimetry [1, 8]. These real-time detectors are rugged, relatively inexpensive and provide on-line readings, what allows for quic...

متن کامل

Characterization of a new commercial single crystal diamond detector for photon- and proton-beam dosimetry

A synthetic single crystal diamond detector (SCDD) is commercially available and is characterized for radiation dosimetry in various radiation beams in this study. The characteristics of the commercial SCDD model 60019 (PTW) with 6- and 15-MV photon beams, and 208-MeV proton beams, were investigated and compared with the pre-characterized detectors: Semiflex (model 31010) and PinPoint (model 31...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 1981