Towards Automated Modelling of Maxillofacial Musculature

نویسندگان

  • G. D. Parker
  • N. Drage
  • P. L. Rosin
  • A. D. Marshall
  • S. Richmond
  • J. Evans
  • D. K. Jones
چکیده

Introduction Patient-specific models of maxillofacial musculature would be of great use in evaluation of prospective surgical treatment options. Due to complex fibre interactions and low image SNR within this region, both diffusion tensor MRI (DT-MRI [1]) and diffusion spectrum imaging [2] have been precluded from use despite previous application to large muscles (due to inability to resolve crossing fibre [3] and SNR concerns regarding b-value requirements respectively), thus directing our focus towards constrained spherical harmonic deconvolution [4] (CSD). CSD assumes that fibre orientation densities (FOD's) may be derived through deconvolution of an idealised (calibrated) single fibre response function from one fit to the target diffusion weighted signal, yielding information regarding fibre orientations. Current datadriven calibration techniques make assumptions connecting the fractional anisotropy (FA) of a signal to the likelihood that it represents a single fibre, averaging the spherical basis functions of the most anisotropic components of an image (typically 0.8>FA>1 [4]) to derive an idealised response. While such techniques work adequately with highly anisotropic target fibres (e.g. white matter), they are neither directly applicable (producing FOD artefacts when deconvolved from low anisotropy targets, e.g. muscle) nor adaptable (muscle fibre is not unique within its FA range) to maxillofacial use. In this work we propose a novel automated tissuespecific calibration technique and provide preliminary results of unsupervised muscle segmentation through affinity propagation clustering [5]. Materials and Methods Using a GE 3T HDx system with an 8 channel brain imaging array images were acquired according to a 60 direction, 6 b0, 450s/mm b-val, 3x3x3mm voxel resolution, TR/TE = 12/103ms protocol. Subsequent CSD (lmax = 8) tracking reconstructions employ a regular 2x2x2mm seed point grid, step size of 0.5mm and termination criteria of 25 angular deviation or a maximum FOD magnitude below 0.1. Three specific calibration strategies are examined (1) Blind application of a 'conventional' 0.8<FA<1 calibration scheme. (2) Exemplar calibration – highly constrained DT-MRI streamlines (5 angular threshold ensuring tracking only along straight fibres) are initiated from way points manually positioned across fibrous structures with the desired diffusive properties (ensuring tissue specificity), basis functions from voxels intersected by these streamlines are averaged to generate the response. Samples of the spinalis capitis (muscle specific) and spinal cord (moderate FA to aid discussion) are selected as exemplars. (3) Automated calibration – Voxel-wise coherence (Eq 1) is calculated across the image: those voxels demonstrating high coherence (i.e. all voxels within straight fibrous structures) are selected. To obtain tissue-specificity, results are filtered by predetermined mean diffusivity and FA ranges (e.g. MD of muscle ≈ 0.014mm/s, approximately twice that of white matter). Basis functions from remaining voxels are averaged to create the fiber response. A coherence threshold of 0.8 (0-1), MD range of 1.43x10 ± 0.49x10mm/s (mean MD over a sample of masseter muscle ± one standard deviation) and FA of 0.321 ± 0.13 (again mean masseter value ± one SD) were selected. Results are judged by consistency with known anatomy. Initial comparisons focused on simple large structures, i.e. the masseter and temporalis muscles, as a means of validating general applicability; proceeding to investigation of crossing fibre resolution through reconstructions of the buccinator and risorius – both of which share roughly orthogonal intersections with the masseter. To assess unsupervised segmentation, manually selected fibre tracts (those representing the temporalis and masseter in the case of Fig.1b) are combined to generate model tractography for an anatomical region. Affinity propagation clustering [5]a technique requiring no a priori knowledge of the expected number of clusters is then applied via the medium of between-tract asymmetric Hausdorff distance measures [6] and outcomes judged by concurrence with manual segmentation. Results In general, conventional (FA-based) calibration produces incomplete reconstructions due to premature tract termination in areas of low anisotropy or high curvature. Spinal calibration exhibits similar failings, albeit to a lower degree. Tissue specific calibrations do not possess such artefacts, producing anatomically plausible reconstructions where data quality allows (see discussion). Direct comparison between the two tissue specific calibrations indicates neither possesses a clear advantage. Unsupervised reconstruction successfully delineates the two muscle groups in that there is no shared membership of any one cluster by the two muscles. However, intriguingly, the cluster-based segmentation also yields sub-divisions within a muscle. Discussion As expected, fibre tracking through conventional CSD calibration produces flawed results. A combination of genuine fibre curvature and errors introduced to the FOD through inappropriate calibration produces “between-step” deviations sufficient to exceed the 25 angular threshold causing the observed premature terminations. Increasing angular thresholds is not a viable solution; the primary effect of CSD miscalibration is the appearance of spurious fibre indications at approximately 55 , 90 and 125 to the correct fibre orientation. Thus, in cases where premature termination has occurred, angles subtended between an artefactual fibre at 55 and the incoming vector are often lower than those subtended by the true orientation, causing tractography to follow phantom fibre (detailed study is beyond the scope of this work). Progressive improvements from conventional calibration (FA=0.8+) through spinal exemplar (0.48) to muscle-specific calibrations (~0.32) clearly imply a correlation between solution quality and calibration discrepancy (difference between calibration and ideal FA's), reinforcing our assertion that specific calibration is necessary. Additionally, parity between manual and automated calibration indicates that, for the novice user, our fully automated method may provide a suitable “black box” approach to data-driven CSD calibration, ideal for application in the clinical environment. There is still room for improvement in image acquisition to minimize susceptibility-induced distortions adjacent to the mouth, which often prevents complete reconstruction of the risorius and buccinator muscles (manifesting as premature termination with the cheek). Fortunately however, the regions of interest (contact patches with the masseter muscle) are sufficiently intact to permit clear indications of crossing fibre resolution under all calibration methods, highlighting the promise of CSD in this area of research. The ability to delineate muscles through unsupervised means is encouraging. Subdivisions found by the clustering within a muscle may reflect important layering or differences in pennation angle, both of which would provide additional (surgically useful) information. Future work will be undertaken to differentiate between important and trivial subdivisions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

Retrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system

Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...

متن کامل

Towards the Automated Modelling and Formal Verification of Analog Designs

Towards the Automated Modelling and Formal Verification of Analog Designs

متن کامل

Maxillary, mandibular, and chin advancement: treatment planning based on airway anatomy in obstructive sleep apnea.

Surgical correction of obstructive sleep apnea (OSA) syndrome involves understanding a number of parameters, of which the 3-dimensional airway anatomy is important. Visualization of the upper airway based on cone beam computed tomography scans and automated computer analysis is an aid in understanding normal and abnormal airway conditions and their response to surgery. The goal of surgical trea...

متن کامل

The potential of teaching modelling problems in the national curriculum for changing students’ attitude towards mathematics

The National curriculum of Islamic Republic of Iran has been focused on promoting students’ modeling skills. In consideration of this emphasis, this study has investigated the attitudes towards mathematics and the views towards mathematical modeling problems of 244 students in grade 10. This research was conducted with a pre-test, followed by an educational intervention and a post-test. During ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010