The development and validation of dried blood spots for external quality assurance of syphilis serology
نویسندگان
چکیده
BACKGROUND Syphilis causes up to 1,500,000 congenital syphilis cases annually. These could be prevented if all pregnant women were screened, and those with syphilis treated with a single dose of penicillin before 28 weeks gestation. In recent years, rapid point-of-care tests have allowed greater access to syphilis screening, especially in rural or remote areas, but the lack of quality assurance of rapid testing has been a concern. We determined the feasibility of using dried blood spots (DBS) as specimens for quality assurance of syphilis serological assays. METHODS We developed DBS extraction protocols for use with Treponema pallidum particle agglutination assay (TPPA), Treponema pallidum haemagglutination assay (TPHA) and an enzyme immunoassay (EIA) and compared the results with those using matching plasma samples from the same patient. RESULTS Since DBS samples showed poor performance with TPHA and EIA (TPHA sensitivity was 50.5% (95% confidence interval: 39.9-61.2%) and EIA specificity was 50.4% (95% CI: 43.7-57.1%), only the DBS TPPA was used in the final evaluation. DBS TPPA showed an sensitivity of 95.5% (95% CI: 91.3-98.0%) and a specificity of 99.0% (95% CI: 98.1-99.5%) compared to TPPA using plasma samples as a reference. CONCLUSION DBS samples can be recommended for use with TPPA, and may be of value for external quality assurance of point-of-care syphilis testing.
منابع مشابه
The implementation of an external quality assurance method for point- of- care tests for HIV and syphilis in Tanzania
BACKGROUND External quality assurance (EQA) programmes, which are routinely used in laboratories, have not been widely implemented for point-of- care tests (POCTs). A study was performed in ten health centres in Tanzania, to implement the use of dried blood spots (DBS) as an EQA method for HIV and syphilis (POCTs). METHOD DBS samples were collected for retesting at a reference laboratory and ...
متن کاملDesign and implementation of an external quality assessment program for HIV viral load measurements using dried blood spots.
An external quality assurance program was developed for HIV-1 RNA viral load measurements taken from dried blood spots using a reference panel and field-collected specimens. The program demonstrated that accurate and reproducible quantitation can be obtained from field-collected specimens. Residual proviral DNA may confound interpretation in virologically suppressed subjects.
متن کاملExternal quality assurance with dried tube specimens (DTS) for point-of-care syphilis and HIV tests: experience in an indigenous populations screening programme in the Brazilian Amazon.
OBJECTIVES The availability of point-of-care (POC) tests for infectious diseases has revolutionised the provision of healthcare for remote rural populations without access to laboratories. However, quality assurance for POC tests has been largely overlooked. We have evaluated the use and stability of dry tube specimens (DTS) for External Quality Assurance (EQA) for HIV and syphilis screening in...
متن کاملI-4: External Quality Assessment - A Necessity in The Andrology Laboratory
Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...
متن کاملValidation and development of an immunonephelometric assay for the determination of alpha-1 antitrypsin levels in dried blood spots from patients with COPD*
OBJECTIVE To validate and develop an immunonephelometric assay for the determination of alpha-1 antitrypsin (AAT) levels in dried blood spots from COPD patients in Brazil. METHODS We determined AAT levels in serum samples and dried blood spots from 192 COPD patients. For the preparation of dried blood spots, a disk (diameter, 6 mm) was placed into a tube, eluted with 200 µL of PBS, and stored...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -