Innovative Methodology Influence of noninvasive peripheral arterial blood pressure measurements on assessment of dynamic cerebral autoregulation
نویسندگان
چکیده
Sammons EL, Samani NJ, Smith SM, Rathbone WE, Bentley S, Potter JF, Panerai RB. Influence of noninvasive peripheral arterial blood pressure measurements on assessment of dynamic cerebral autoregulation. J Appl Physiol 103: 369–375, 2007. First published April 26, 2007; doi:10.1152/japplphysiol.00271.2007.—Assessment of dynamic cerebral autoregulation (CA) requires continuous recording of arterial blood pressure (ABP). In humans, noninvasive ABP recordings with the Finapres device have often been used for this purpose. We compared estimates of dynamic CA derived from Finapres with those from invasive recordings in the aorta. Measurements of finger noninvasive ABP (Finapres), intra-aortic ABP (Millar catheter), surface ECG, transcutaneous CO2, and bilateral cerebral blood flow velocity (CBFV) in the middle cerebral arteries were simultaneously and continuously recorded in 27 patients scheduled for percutaneous coronary interventions. Phase, gain, coherence, and CBFV step response from both the Finapres and intra-arterial catheter were estimated by transfer function analysis. A dynamic autoregulation index (ARI) was also calculated. For both hemispheres, the ARI index and the CBFV step response recovery at 4 s were significantly greater for the Finapres-derived estimates than for the values obtained from aortic pressure. The transfer function gain for frequencies 0.1 Hz was significantly smaller for the Finapres estimates. The phase frequency response was significantly greater for the Finapres estimates at frequencies 0.1 Hz, but not at lower frequencies. The Finapres gives higher values for the efficiency of dynamic CA compared with values derived from aortic pressure measurements, as indicated by biases in the ARI index, CBFV step response, gain, and phase. Despite the significance of these biases, their relatively small amplitude indicates a good level of agreement between indexes of CA derived from the Finapres compared with corresponding estimates obtained from invasive measurements of aortic ABP.
منابع مشابه
Influence of noninvasive peripheral arterial blood pressure measurements on assessment of dynamic cerebral autoregulation.
Assessment of dynamic cerebral autoregulation (CA) requires continuous recording of arterial blood pressure (ABP). In humans, noninvasive ABP recordings with the Finapres device have often been used for this purpose. We compared estimates of dynamic CA derived from Finapres with those from invasive recordings in the aorta. Measurements of finger noninvasive ABP (Finapres), intra-aortic ABP (Mil...
متن کاملGrading of dynamic cerebral autoregulation without blood pressure recordings: a simple Doppler-based method.
Transcranial Doppler sonography allows for noninvasive assessment of dynamic cerebral autoregulation. A wider clinical use of this approach has been hampered by the need for continuous arterial blood pressure (ABP) measurements. We describe a new method of a pure Doppler signal based estimation of dynamic autoregulation using heart rate (HR) and cerebral blood flow velocity (CBFV) information. ...
متن کاملGrading of cerebral dynamic autoregulation from spontaneous fluctuations in arterial blood pressure.
BACKGROUND AND PURPOSE Assessment of cerebral autoregulation has been traditionally performed with static changes in arterial blood pressure. Newer dynamic methods require the induction of sudden drops in arterial blood pressure with the sudden release of bilateral thigh cuffs. An alternative method is proposed, based on the spontaneous variability of arterial blood pressure that does not requi...
متن کاملNoninvasive evaluation of dynamic cerebrovascular autoregulation using Finapres plethysmograph and transcranial Doppler.
BACKGROUND AND PURPOSE Mx is an index of cerebrovascular autoregulation. It is calculated as the correlation coefficient between slow spontaneous fluctuations of cerebral perfusion pressure (cerebral perfusion pressure=arterial blood pressure-intracranial pressure) and cerebral blood flow velocity. Mx can be estimated noninvasively (nMxa) with the use of a finger plethysmograph arterial blood p...
متن کاملComparison of static and dynamic cerebral autoregulation measurements.
BACKGROUND AND PURPOSE Cerebral autoregulation can be evaluated by measuring relative blood flow changes in response to a steady-state change in the blood pressure (static method) or during the response to a rapid change in blood pressure (dynamic method). The purpose of this study was to compare the results of the two methods in humans with both intact and impaired autoregulatory capacity. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007