Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes.

نویسنده

  • Rosanna Fiallo-Scharer
چکیده

CONTEXT Advantages/disadvantages of continuous vs. discrete glucose monitoring are not well documented. OBJECTIVE Compare glucose profiles from home meters vs. continuous sensors. DESIGN Randomized clinical trial conducted by the Diabetes Research in Children Network (DirecNet) to assess the utility of the GlucoWatch G2 Biographer. SETTING Home glucose measurements. PATIENTS Two hundred children (age, 7 to < 18 yr) with type 1 diabetes. INTERVENTION At baseline, subjects were asked to wear the continuous glucose monitoring system (CGMS) sensor and perform meter tests at eight prespecified times of the day (eight-point testing) each for 3 d (2 d using both, 1 d eight-point testing only, 1 d CGMS only). Hemoglobin A1c was measured in a central laboratory. MAIN OUTCOME MEASURE Six-month hemoglobin A1c. This analysis looked at baseline glucose profiles/hemoglobin A1c. RESULTS Only 10% of subjects completed full eight-point testing for 3 d, but median CGMS use was 70 h. Mean glucose was lower when measured by the CGMS compared with eight-point testing (183 +/- 37 vs. 188 +/- 41 mg/dl; 10.2 +/- 2.1 vs.10.4 +/- 2.3 mmol/liter; P = 0.009), especially overnight (2400-0400 h; 174 vs. 199 mg/dl; 9.7 vs. 11.1 mmol/liter; P < 0.001). Associations of hemoglobin A1c with mean glucose were similar for eight-point testing [slope 23 mg/dl per 1% (1.3 mmol/liter); correlation 0.40; P < 0.001] and CGMS [slope 19 mg/dl per 1% (1.1 mmol/liter); correlation 0.39; P < 0.001]. Postprandial excursions were lower for eight-point testing vs. CGMS, especially after dinner (mean excursion -17 vs. 63 mg/dl; -1.0 vs. 3.5 mmol/liter; P < 0.001). CONCLUSIONS Both methods gave similar mean glucose profiles and associations with hemoglobin A1c. Advantages of the CGMS were higher density of data and better detection of postprandial peaks. However, the CGMS may overestimate the frequency of low glucose levels, especially overnight.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Four Weeks Continuous Aerobic Training on Liver Transaminases and Glycemic Markers in Women with Type II Diabetes

Fatty liver disease is one of the most common diseases in women with type II diabetes. While regular exercise can decrease the complication of this disease, it was not clearly identified. The aim of this study was to evaluate the effect of four weeks aerobic training on Liver Transaminases and some glycemic markers in women with type II diabetes.Materials and Methods: In this study, 20 patients...

متن کامل

The Effect of Eight Weeks Aerobic Training on Serum Ferritin Level, Glycemic and Lipid Indices in Women with Type 2 Diabetes

Background and Aim: Recent studies indicate that increased body iron stores have been associated with the development of glucose intolerance and type 2 Diabetes. Ferritin is the most important iron storage protein in the body, which is used to evaluate disorders associated with iron metabolism. The aim of this study was to examine the effect of eight weeks of aerobic training on serum ferritin ...

متن کامل

Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring.

I ntensive self-management with frequent self-monitoring of blood glucose (SMBG) is important in type 1 diabetes to achieve good metabolic control (1–3). Nevertheless, many patients still experience episodes of unrecognized hypoand hyperglycemia (4). Novel technologies for continuous glucose monitoring (CGM) that provide information about glucose excursions are now available. Previous studies r...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

Comparison between adherence assessments and blood glucose monitoring measures to predict glycemic control in adults with type 1 diabetes: a cross-sectional study

BACKGROUND Adherence to treatment has been defined as the degree to which a patient's behavior corresponds to medical or health advice; however, the most appropriate method to evaluate adherence to diabetes care has yet to be identified. We conducted analyses to compare adherence assessments and blood glucose monitoring measures with regard to their ability to predict glycemic control in adults...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical endocrinology and metabolism

دوره 90 6  شماره 

صفحات  -

تاریخ انتشار 2005