In elastography, the tissue under investigation is compressed and the resulting strain is estimated from the gradient of the displacement (time-delay) estimates. The displacements are typically estimated by crosscorrelating the radiofrequency (RF) ultrasound signals of the preand postcompressed tissue. One of the parameters used to quantify the resulting quality of the elastogram is the elastographic signal-to-noise ratio (SNRe). For a uniformly elastic target (a single elastic modulus), the dependence of the SNRe on the applied strain has a bandpass characteristic that has been termed the strain filter. Theoretical expressions for the upper bound on the strain filter were developed earlier. Yet, simulated as well as experimental strain filters derived from uniformly elastic phantoms deviate from these upper bounds. The failure to achieve the upper bounds could be partially attributed to the fact that, in both simulations and experiments, the RF signals used to compute the TDEs are sampled and quantized. Using simulated models of uniformly elastic phantoms, a study of the dependence of the strain filter on the quantization and sampling rates was performed. The results indicated that the strain filter improves with both the sampling rate and the quantization, as expected. A theoretical analysis was done to incorporate quantization as a derating factor to the strain filter. (E-mail: [email protected]) © 2002 World Federation for Ultrasound in Medicine & Biology.
منابع مشابه
Pii: S0301-5629(02)00507-0
A clinical study of the concept “wide-focus and low-pressure” extracorporal shock-wave lithotripsy (ESWL) was performed in a scientific cooperation between the Physical Institute of the University of Stuttgart and the Xixin Medical Instruments Co. Ltd. in Wuxian-Suzhou, China. In this cooperation, self-focusing electromagnetic shock-wave generator systems from the University of Stuttgart were i...
متن کاملPii: S0301-5629(02)00550-1
In this paper, a pilot study regarding carotid atherosclerotic plaque instability using B-mode ultrasound (US) images was carried out. The fractal dimension of plaques obtained from ten symptomatic subjects (i.e., subjects having experienced neurological symptoms) as well as from nine asymptomatic subjects, was estimated using a novel method, called the kth nearest neighbour (KNN) method. The r...
متن کاملPii: S0301-5629(01)00472-0
The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estima...
متن کاملPii: S0301-5629(02)00488-x
Early detection of cardiovascular diseases has been a very active research area in the medical imaging field. Assessment of the local and global mechanical functions is one of the major goals of accurate diagnosis. In this study, we investigated the feasibility of elastography for estimation and imaging of the local cardiac muscle displacement and strain in a human heart in vivo. In its noninva...
متن کاملPii: S0301-5629(01)00391-x
The use of liquid brominated hydrocarbons to form a planar reflecting interface with water is described. Gravity-based planar reflecting surfaces with known reflection coefficients can be used in system characterization for quantitative ultrasonics, and a set of surfaces with a range of reflection coefficients allows calibration of the output power and receiver gain of ultrasonic imaging system...