Clotting Phenomena at the Blood-Polymer Interface and Development of Blood Compatible Polymeric Surfaces

نویسنده

  • Adriaan Bantjes
چکیده

In the past two decades many attempts have been made t o relate surface and interfacial parameters with the blood compatibility of polymeric surfaces. It is however doubtful if by a single parameter the behaviour of blood on a surface can be predicted. Two major aspects of blood compatibility -the prevention of platelet adhesion and the deactivation of the intrinsic coagulation system are determined by the measure and nature of competitive blood protein adsorption on the foreign surface. The adhesion of blood platelets is promoted by adsorbed fibrinogen and gamma globulin, while adsorbed albumin inhibits platelct adhesion. Heparinised surfaces d o not adsorb fibrin and consequently no adhesion of platelets takes place. Othcr surfaces with low platelct adhesion are the hydrogels, certain block copolyetherurethanes, polyelectrolyte complexes and biolised proteins. Heparinised surfaces of the cationically bonded type inhibit the intrinsic coagulation as well, however this may be due to unstable coatings and heparin leakage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization of Short-Chain Polyphosphate Enhances its Ability to Clot Flowing Blood Plasma

Short-chain polyphosphate (polyP) is released from platelets upon platelet activation, but it is not clear if it contributes to thrombosis. PolyP has increased propensity to clot blood with increased polymer length and when localized onto particles, but it is unknown whether spatial localization of short-chain polyP can accelerate clotting of flowing blood. Here, numerical simulations predicted...

متن کامل

Constitutive modeling of macromolecular fluids

Macromolecular or polymeric liquids consist of polymer solutions, polymer melts, particle suspension fluids, and many biological fluids. Polymer solutions are made of polymers dissolved in solutions or solvent; polymer melts are molten polymers; particle suspension fluids consist of solid particles suspended in a matrix fluid which may be a viscous or viscoelastic fluid, blood flows consist of ...

متن کامل

Development of a rheological model for polymeric fluids based on FENE model

Rheological models for polymer solutions and melts based on the finitely extensible non-linear elastic (FENE) dumbbell theory are reviewed in this study. The FENE-P model that is a well-known Peterlin approximation of the FENE model, indicates noticeable deviation from original FENE predictions and also experimental results, especially in the transient flow. In addition, both FENE and FENE-P mo...

متن کامل

The use of the ex vivo Chandler Loop Apparatus to assess the biocompatibility of modified polymeric blood conduits.

The foreign body reaction occurs when a synthetic surface is introduced to the body. It is characterized by adsorption of blood proteins and the subsequent attachment and activation of platelets, monocyte/macrophage adhesion, and inflammatory cell signaling events, leading to post-procedural complications. The Chandler Loop Apparatus is an experimental system that allows researchers to study th...

متن کامل

Detection of Polymer Brushes developed via Single Crystal Growth

Single crystals consisting various surface morphologies and epitaxial structures were applied to investigate the effect of other phase regions in the vicinity of a given tethered chains-covered area having a certain molecular weight of amorphous brushes. The designed experiments demonstrated that regardless of the type of surface morphology (patterned and especial mixed-brushes, homo and co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006