Within- and between-session reliability of medial gastrocnemius architectural properties

نویسندگان

  • JJ McMahon
  • A Turner
  • P Comfort
چکیده

This study aimed to determine the within- and between-session reliability of medial gastrocnemius (MG) architecture (e.g. muscle thickness (MT), fascicle length (FL) and pennation angle (PA)), as derived via ultrasonography followed by manual digitization. A single rater recorded three ultrasound images of the relaxed MG muscle belly for both legs of 16 resistance trained males, who were positioned in a pronated position with their knees fully extended and the ankles in a neutral (e.g. 90°) position. A subset of participants (n = 11) were retested under the same conditions ~48-72 hours after baseline testing. The same rater manually digitized each ultrasound image on three occasions to determine MG MT, FL and PA before pooling the data accordingly to allow for within-image (n = 96), between-image (n = 32) and between-session reliability (n = 22) to be determined. Intraclass correlation coefficients (ICCs) demonstrated excellent within-image (ICCs = 0.99-1.00, P < 0.001) and very good between-image (ICCs = 0.83-0.95, P < 0.001) and between-session (ICCs = 0.89-0.95, P < 0.001) reliability for MT, FL and PA. Between-session coefficient of variation was low (≤ 3.6%) for each architectural parameter and smallest detectible difference values of 10.6%, 11.4% and 9.8% were attained for MT, FL and PA, respectively. Manually digitizing ultrasound images of the MG muscle at rest yields highly reliable measurements of its architectural properties. Furthermore, changes in MG MT, FL and PA of ≥ 10.6%, 11.4% and 9.8% respectively, as brought about by any form of intervention, should be considered meaningful.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of Ultrasound Measures of M. Gastrocnemius Pennation Angle

There are currently few studies in the literature concerning the reliability and validity of the quantification of parameters of muscle architecture using the technique of ultrasound. The aim of this study is to apply the technique of ultrasound imaging to quantify pennation angle of gastrocnemius muscle (medial and lateral) and to determine the reliability and reproducibility of these measures...

متن کامل

The Intra- and Inter-Rater Reliability of an Instrumented Spasticity Assessment in Children with Cerebral Palsy

AIM Despite the impact of spasticity, there is a lack of objective, clinically reliable and valid tools for its assessment. This study aims to evaluate the reliability of various performance- and spasticity-related parameters collected with a manually controlled instrumented spasticity assessment in four lower limb muscles in children with cerebral palsy (CP). METHOD The lateral gastrocnemius...

متن کامل

Reliability correction for functional connectivity: Theory and implementation.

Network properties can be estimated using functional connectivity MRI (fcMRI). However, regional variation of the fMRI signal causes systematic biases in network estimates including correlation attenuation in regions of low measurement reliability. Here we computed the spatial distribution of fcMRI reliability using longitudinal fcMRI datasets and demonstrated how pre-estimated reliability maps...

متن کامل

Reliability and Validity of the OMNI-Vibration Exercise Scale of Perceived Exertion.

UNLABELLED This study examined reliability and concurrent validity of the newly developed OMNI-vibration exercise scale (OMNI-VIBRO) to measure Ratings of Perceived Exertion (RPE) during vibration exercise in twenty recreationally active students (12 males and 8 females). The criterion variables were muscle activity of the Vastus Medialis (VM), Vastus Lateralis (VL), Biceps Femoris (BF), and Me...

متن کامل

Comparison of Ultrasonographic Architectural Properties and Balance Ability Based on the Muscle Contraction of Chronic Stroke Patients

The purpose of this study is to compare the ultrasonographic architectural properties of muscles and balance ability based on the muscle contraction of chronic stroke patients. The subjects of this study were 30 chronic stroke patients were divided into 3 classes based on the Modified Ashworth Scale (MAS), with 10 patients in each class. Ultrasonographic architectural properties and balance abi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2016