Precise Zn isotopic ratio measurements of human red blood cell and hair samples by multiple collector-ICP-mass spectrometry.

نویسندگان

  • Takeshi Ohno
  • Atsuko Shinohara
  • Momoko Chiba
  • Takafumi Hirata
چکیده

Precise 66Zn/64Zn and 68Zn/64Zn isotopic ratios of biochemical samples have been measured using multiple collector-ICP-mass spectrometry (MC-ICPMS). In order to eliminate the mass spectrometric interferences on Zn isotopes (e.g., 64Ni+ and 136Ba2+), we chemically purified the analyte using an ion chromatographic technique. The resulting precisions of the 66Zn/64Zn and 68Zn/64Zn ratio measurements were 0.05/1000 and 0.10/1000 (2SD), respectively, which were enough to detect the isotopic variation of Zn in nature. Red blood cell (RBC) samples were collected from five volunteers (four males and one female), including a series of 12 RBC samples from one person through monthly-based sampling over a year. These were analyzed to test possible seasonal changes and variations in 66Zn/64Zn and 68Zn/64Zn ratios among the individuals. The 66Zn/64Zn and 68Zn/64Zn ratios for a series of 12 RBC samples collected over a year were 0.43/1000 and 0.83/1000 higher than the values of highly purified Zn metal (JMC Zn), and no seasonal change could be found. The 66Zn/64Zn and 68Zn/64Zn ratios for RBC samples collected from five volunteers did not vary significantly. In order to investigate Zn isotopic heterogeneity in a human body, Zn isotopic ratios of a hair sample collected from one of the volunteers was also analyzed. The 66Zn/64Zn and 68Zn/64Zn ratios for the hair sample were 0.59/1000 and 1.14/1000 lower than the mean value of RBC samples. This result demonstrates that detectable isotopic fractionation occurs in the human body. The data obtained here suggest that the isotopic ratios of trace metals could provide new information about transportation of metal elements in vivo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Precision Zinc Stable Isotope Measurement of Certified Biological Reference Materials Using the Double Spike Technique and Multiple Collector-ICP-MS

Biological reference materials with well-characterised stable isotope compositions are lacking in the field of 'isotope biochemistry', which seeks to understand bodily processes that rely on essential metals by determining metal stable isotope ratios. Here, we present Zn stable isotope data for six biological reference materials with certified trace metal concentrations: fish muscle, bovine mus...

متن کامل

Isotopic analysis of Fe in human red blood cells by multiple collector-ICP-mass spectrometry.

Precise 56Fe/54Fe and 57Fe/54Fe isotopic ratios on human red blood cell (RBC) samples have been measured using multiple collector-ICP-mass spectrometry (MC-ICPMS). The mass spectrometric interferences on Fe isotopes (e.g., 56ArO+ and 57ArOH+) were successfully minimized by a dry plasma condition achieved by a desolvating nebulizer sample-introduction technique. In order to eliminate possible va...

متن کامل

Selected isotope ratio measurements of light metallic elements (Li, Mg, Ca, and Cu) by multiple collector ICP-MS

The unique capabilities of multiple collector inductively coupled mass spectrometry (MC-ICP-MS) for high precision isotope ratio measurements in light elements as Li, Mg, Ca, and Cu are reviewed in this paper. These elements have been intensively studied at the Geological Survey of Israel (GSI) and other laboratories over the past few years, and the methods used to obtain high precision isotope...

متن کامل

Reduction of UH formation for U/U isotope ratio measurements at ultratrace level in double focusing sector field ICP-MS using D2O as solvent

The main factors affecting the accurate and precise determination of U using ICP-MS are instrumental background, the isobaric interference of UH molecular ion on U analyte ions, and the presence of U and U peak tails. An optimized analytical method for attenuating the influence of these factors on uranium isotope ratio measurements at ultratrace level of environmental samples has been developed...

متن کامل

Erratum: Measurement of zinc stable isotope ratios in biogeochemical matrices by double-spike MC-ICPMS and determination of the isotope ratio pool available for plants from soil

Analysis of naturally occurring isotopic variations is a promising tool for investigating Zn transport and cycling in geological and biological settings. Here, we present the recently installed double-spike (DS) technique at the MAGIC laboratories at Imperial College London. The procedure improves on previous published DS methods in terms of ease of measurement and precisions obtained. The anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2005