Are extreme distal periprosthetic supracondylar fractures of the femur too distal to fix using a lateral locked plate?

نویسندگان

  • P N Streubel
  • M J Gardner
  • S Morshed
  • C A Collinge
  • B Gallagher
  • W M Ricci
چکیده

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic component. Between 1999 and 2008, 89 patients underwent lateral locked plating of a supracondylar periprosthetic femoral fracture, of whom 61 patients with a mean age of 72 years (42 to 96) comprising 53 women, were available after a minimum follow-up of six months or until fracture healing. Patients were grouped into those with fractures located proximally (28) and those with fractures that extended distal to the proximal border of the femoral component (33). Delayed healing and nonunion occurred respectively in five (18%) and three (11%) of more proximal fractures, and in two (6%) and five (15%) of the fractures with distal extension (p = 0.23 for delayed healing; p = 0.72 for nonunion, Fisher's exact test). Four construct failures (14%) occurred in more proximal fractures, and three (9%) in fractures with distal extension (p = 0.51). Of the two deep infections that occurred in each group, one resolved after surgical debridement and antibiotics, and one progressed to a nonunion. Extreme distal periprosthetic supracondylar fractures of the femur are not a contra-indication to lateral locked plating. These fractures can be managed with internal fixation, with predictable results, similar to those seen in more proximal fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intramedullary nailing versus locked plate for treating supracondylar periprosthetic femur fractures.

The objective of this study was to compare retrograde intramedullary femoral nailing with supracondylar locked screw-plate fixation for the treatment of periprosthetic femur fractures following total knee arthroplasty. Time to union and full weight bearing were the primary study outcomes, with perioperative blood loss, need for transfusion, need for revision surgery, and infection being the sec...

متن کامل

Immediate weight bearing of comminuted supracondylar femur fractures using locked plate fixation.

Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, som...

متن کامل

Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty.

OBJECTIVE New locked plate devices offer theoretical advantages for the treatment of supracondylar femur fractures associated with a total knee arthroplasty (TKA). These devices also can be inserted with relative ease by using minimally invasive techniques, provide a fixed angle construct, and improve fixation in osteoporotic bone. The purpose of this study was to evaluate the results and compl...

متن کامل

The Outcome and Complications of the Locked Plating Management for the Periprosthetic Distal Femur Fractures after a Total Knee Arthroplasty

BACKGROUND The osteosynthesis of the periprosthetic fractures following a total knee arthroplasty (TKA) can be technically difficult with the relatively small satisfactory outcomes and the high complication rates. The purpose of the study is to analyze the mid-term radiological and functional outcomes following the locked plating of the distal femur periprosthetic fractures after a TKA. METHO...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 4  شماره 

صفحات  -

تاریخ انتشار 2010