Influence of absorption and scattering on the quantification of fluorescence diffuse optical tomography using normalized data.
نویسندگان
چکیده
Reconstruction algorithms for imaging fluorescence in near infrared ranges usually normalize fluorescence light with respect to excitation light. Using this approach, we investigated the influence of absorption and scattering heterogeneities on quantification accuracy when assuming a homogeneous model and explored possible reconstruction improvements by using a heterogeneous model. To do so, we created several computer-simulated phantoms: a homogeneous slab phantom (P1), slab phantoms including a region with a two- to six-fold increase in scattering (P2) and in absorption (P3), and an atlas-based mouse phantom that modeled different liver and lung scattering (P4). For P1, reconstruction with the wrong optical properties yielded quantification errors that increased almost linearly with the scattering coefficient while they were mostly negligible regarding the absorption coefficient. This observation agreed with the theoretical results. Taking the quantification of a homogeneous phantom as a reference, relative quantification errors obtained when wrongly assuming homogeneous media were in the range +41 to +94% (P2), 0.1 to -7% (P3), and -39 to +44% (P4). Using a heterogeneous model, the overall error ranged from -7 to 7%. In conclusion, this work demonstrates that assuming homogeneous media leads to noticeable quantification errors that can be improved by adopting heterogeneous models.
منابع مشابه
Engineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)
Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...
متن کاملImproved quantification of small objects in near-infrared diffuse optical tomography.
Diffuse optical tomography allows quantification of hemoglobin, oxygen saturation, and water in tissue, and the fidelity in this quantification is dependent on the accuracy of optical properties determined during image reconstruction. In this study, a three-step algorithm is proposed and validated that uses the standard Newton minimization with Levenberg-Marquardt regularization as the first st...
متن کاملA Study on the Aggregation and Calf Thymus DNA Binding Characteristics of Anionic Cobalt(II) Tetrasulfonated Phthalocyanine
The aggregation behavior of anionic Cobalt(II) 4,4′,4ʺ,4‴-tetrasulfonated phthalocyanine, [Co(TSPc)4-] was studied at its various concentrations and different ionic strengths using optical absorption and resonance light scattering (RLS) spectroscopies in 5 mM phosphate buffer, pH 7.0 at 25 °C. The results show no aggregation behavior at concentration range of 5.1 × 10-6-7....
متن کاملReconstruction of an optical inhomogeneity map improves fluorescence diffuse optical tomography
We propose a new reconstruction algorithm for fluorescence diffuse optical tomography, which is designed for highly heterogeneous objects, such as biological tissues. It is a two-step algorithm that exploits continuous-wave measurements acquired at both excitation and fluorescence wavelengths. First, an optical inhomogeneity map, which depends on both absorption and diffusion coefficients, is o...
متن کاملImage quality improvement of diffuse optical tomography of breast tumor using artificial intelligence
This article has no abstract.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2012