Characterization of lens based photoacoustic imaging system☆

نویسندگان

  • Kalloor Joseph Francis
  • Bhargava Chinni
  • Sumohana S. Channappayya
  • Rajalakshmi Pachamuthu
  • Vikram S. Dogra
  • Navalgund Rao
چکیده

Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Laser scanning laser diode photoacoustic microscopy system

The development of low-cost and fast photoacoustic microscopy systems enhances the clinical applicability of photoacoustic imaging systems. To this end, we present a laser scanning laser diode-based photoacoustic microscopy system. In this system, a 905 nm, 325 W maximum output peak power pulsed laser diode with 50 ns pulsewidth is utilized as the light source. A combination of aspheric and cyl...

متن کامل

Simultaneous photoacoustic imaging technique using an acoustic imaging lens.

A simultaneous photoacoustic (PA) tomography imaging technique in multilayer samples was developed. Instead of using the PA image reconstruction methods on the basis of complex algorithms, obtaining a two-dimensional PA image in real time is available by using an acoustic lens that has the ability of parallel imaging. The imaging system can acquire the complete PA signals of high signal-to-nois...

متن کامل

Design of miniaturized illumination for transvaginal co-registered photoacoustic and ultrasound imaging.

A novel lens-array based illumination design for a compact co-registered photoacoustic/ultrasound transvaginal probe has been demonstrated. The lens array consists of four cylindrical lenses that couple the laser beams into four 1-mm-core multi-mode optical fibers with optical coupling efficiency of ~87%. The feasibility of our lens array was investigated by simulating the lenses and laser beam...

متن کامل

In vivo fast variable focus photoacoustic microscopy using an electrically tunable lens.

Fast focusing scan over a large depth range is challenging in photoacoustic microscopic imaging. In this paper, a fast variable focus photoacoustic microscopy (VF-PAM) with a large range of imaging depth was presented by using an electrically tunable lens (ETL). The ETL controlled the divergence angle of the laser beam for fast and continuous focus-shifting in depth direction with the shifting ...