Measurement variability in single-breath diffusing capacity of the lung.

نویسندگان

  • Naresh M Punjabi
  • David Shade
  • Anshul M Patel
  • Robert A Wise
چکیده

STUDY OBJECTIVES The single-breath diffusing capacity of the lung (DLCO) is a commonly performed pulmonary function test. The current American Thoracic Society (ATS) recommendations for reproducibility of DLCO measurements suggest that two measurements for the DLCO agree within 10% or 3 mL/min/mm Hg of the average value. The European Respiratory Society (ERS) recommends that two measurements should agree within 10%. The objectives of the present study were to examine whether the current reproducibility criteria were met in a general pulmonary function laboratory and to determine whether alternative criteria might be appropriate. DESIGN Cross-sectional study. SETTING University-based pulmonary function laboratory. PATIENTS OR PARTICIPANTS Patients referred for spirometry, helium lung volumes, and DLCO measurement. INTERVENTIONS None. MEASUREMENTS AND RESULTS In a sample of 6,193 patients referred for clinical testing, 98.3% had two DLCO values that fulfilled the current ATS criteria for reproducibility. The coefficient of variation (CV) and the percentage difference between two repeat measurements were inversely associated with the baseline DLCO and the FEV(1). As the baseline DLCO (percentage of predicted) or FEV(1) (percentage of predicted) decreased, there was an increase in the CV and the percentage difference. In contrast, the absolute difference between repeat measurements was relatively stable irrespective of the baseline DLCO or FEV(1) values. Other patient factors, such as gender and race, were not associated with measurement variability. Using an absolute difference of 2 to 2.5 mL/min/mm Hg between two DLCO measurements as alternative criteria for reproducibility, 91.5% and 95.8% of the patient sample fulfilled these criteria, respectively. CONCLUSIONS Reproducibility of the DLCO measurement is generally much better than current standards allow. Future standards should consider an absolute difference rather than a percentage difference criterion for DLCO reproducibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary function in status asthmaticus: effect of therapy.

In 11 patients with bronchial asthma, lung volumes, FEV1.0, PaO2, and lung diffusing capacity (single breath CO method) were measured in status asthmaticus and after recovery. Ventilatory capacity improved following therapy. The improvement was associated with a rise in vital capacity and a fall in residual volume, but the total lung capacity might either decrease, increase or remain unchanged....

متن کامل

Effect of lung inflation on pulmonary diffusing capacity at rest and exercise.

Steady state measurements of the diffusing capacity of the lung are made at operational lung volume, whereas measurements by the breath-holding method are customarily made at full inspiration. The effect of lung inflation on diffusing capacity must be taken into account before the steady state and breath-holding methods can be validly compared. At rest the single breath diffusing capacity of th...

متن کامل

Quality control of DL,CO instruments in global clinical trials.

High inter- and intra-laboratory variability exists for the single-breath diffusing capacity of the lung for carbon monoxide (D(L,CO)) test. To detect small changes in diffusing capacity in multicentre clinical trials, accurate measurements are essential. The present study assessed whether regular D(L,CO) simulator testing maintained or improved instrument accuracy and reduced variability in mu...

متن کامل

The Role of EDD (Exercise Capacity, Dyspnea, and Diffusing Capacity of Lungs for Carbon Monoxide) Index in Pulmonary Fibrosis Secondary to Scleroderma

Introduction: Pulmonary involvement secondary to Systemic Sclerosis (SSc) is the major cause of morbidity and mortality in SSc patients. We designed this study to determine the correlation of important lung function parameters with lung High Resolution CT (HRCT) scan findings. Materials and Methods: Thirty–two consecutive diffuse SSc patients with pulmonary fibrosis were enrolled in this cross...

متن کامل

A small amount of inhaled nitric oxide does not increase lung diffusing capacity.

The aim of the present study was to determine: 1) whether 40-50 ppm nitric oxide (NO) increases diffusing capacity of the lung for NO (D(L,NO)) and carbon monoxide (D(L,CO)), membrane diffusing capacity for CO (D(m,CO)) and pulmonary capillary blood volume (V(c)); 2) the actual number of tests required to provide a reasonable estimate of D(L,NO), D(L,CO), D(m,CO) and V(c); and 3) repeatability ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 123 4  شماره 

صفحات  -

تاریخ انتشار 2003