Ultrashort echo time MRI of pulmonary water content: assessment in a sponge phantom at 1.5 and 3.0 Tesla.
نویسندگان
چکیده
PURPOSE We aimed to develop a predictive model for lung water content using ultrashort echo time (UTE) magnetic resonance imaging (MRI) and a sponge phantom. MATERIALS AND METHODS Image quality was preliminarily optimized, and the signal-to-noise ratio (SNR) of UTE was compared with that obtained from a three-dimensional fast gradient echo (FGRE) sequence. Four predetermined volumes of water (3.5, 3.0, 2.5, and 2.0 mL) were soaked in cellulose foam sponges 1.8 cm3 in size and were imaged with UTE-MRI at 1.5 and 3.0 Tesla (T). A multiple echo time experiment (range, 0.1-9.6 ms) was conducted, and the T2 signal decay curve was determined at each volume of water. A three-parameter equation was fitted to the measured signal, allowing for the calculation of proton density and T2*. The calculation error of proton density was determined as a function of echo time. The constants that allowed for the determination of unknown volumes of water from the measured proton density were calculated using linear regression. RESULTS UTE-MRI provided excellent image quality for the four phantoms and showed a higher SNR, compared to that of FGRE. Proton density decreased proportionally with the decreases in both lung water and field strength (from 3.5 to 2.0 mL; proton density range at 1.5 T, 30.5-17.3; at 3.0 T, 84.2-41.5). Minimum echo time less than 0.6 ms at 1.5 T and 1 ms at 3.0 T maintained calculation errors for proton density within the range of 0%-10%. The slopes of the lines for determining the unknown volumes of water with UTE-MRI were 0.12±0.003 at 1.5 T and 0.05±0.002 at 3.0 T (P < 0.0001). CONCLUSION In a sponge phantom imaged at 1.5 and 3.0 T, unknown volumes of water can be predicted with high accuracy using UTE-MRI.
منابع مشابه
Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes
Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...
متن کاملCalculation of total dose and dose equivalent distribution in the treatment of lung cancer using MR-guided carbon therapy
Nowadays, in order to improve the accuracy of treatment in radiation therapy, there are many attempts to use magnetic resonance imaging (MRI) due to the advantages of excellent soft tissue contrast and ultra-fast pulse sequences. On the other hand, carbon-ion radiation therapy is developing rapidly due to the benefits of greater relative biological effectiveness (RBE) and the application in the...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diagnostic and interventional radiology
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2014