Measurement of Regional Lung Function in Rats Using Hyperpolarized Helium Dynamic MRI

نویسندگان

  • Ben T. Chen
  • Anja C.S. Brau
  • Allan Johnson
چکیده

Dynamic regional lung function was investigated in rats using a radial acquisition cine (RA-CINE) pulse sequence together with hyperpolarized (HP) He gas delivered by a constant flow ventilator. Based on regional differences in the behavior of inspired air, the lung was conceptually divided into two regions (the major airways and the peripheral airspace) for purposes of functional analysis. To measure regional function in the major airways, a large RF flip angle (24°) was applied to reduce He magnetization in the peripheral airspace, and signal intensity (SI) was normalized with the projected airway diameter to estimate local airflow. Higher normalized signal intensity was observed in the left branch airway as compared to the right branch airway. To determine regional function in the peripheral airspace, a small RF flip angle (6°) was used. Incremental increases of peripheral SI in successive lung images were consistent with the increase in lung volume. A new “skipping” scanning strategy using dummy frames allows a trade-off between the number of frames acquired for dynamic information, the RF flip angle, and the penetration depth of He magnetization into the lung. This work provides a novel approach to simultaneously assess dynamic regional function and morphology. Magn Reson Med 49:78–88, 2003. © 2003 Wiley-Liss, Inc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating bronchodilator effects in chronic obstructive pulmonary disease using diffusion-weighted hyperpolarized helium-3 magnetic resonance imaging.

The objective of this study was to evaluate the regional effects of bronchodilator administration in chronic obstructive pulmonary disease (COPD) using hyperpolarized helium-3 ((3)He) MRI apparent diffusion coefficient (ADC). Ten COPD ex-smokers provided written, informed consent and underwent diffusion-weighted, hyperpolarized (3)He MRI, spirometry, and plethysmography before and 25 ± 2 min af...

متن کامل

Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI.

Dynamic regional lung function was investigated in rats using a radial acquisition cine (RA-CINE) pulse sequence together with hyperpolarized (HP) (3)He gas delivered by a constant flow ventilator. Based on regional differences in the behavior of inspired air, the lung was conceptually divided into two regions (the major airways and the peripheral airspace) for purposes of functional analysis. ...

متن کامل

Iology Contribution Proton and Hyperpolarized Helium Magnetic Resonance Imaging of Radiation-induced Lung Injury in Rats

Purpose: To assess the usefulness of hyperpolarized helium (He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. Methods and Materials: Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 8 Gy) using 4-MV photons. Conventional proton (H) and hyperpolarized (He) MRI were use...

متن کامل

Proton and hyperpolarized helium magnetic resonance imaging of radiation-induced lung injury in rats.

PURPOSE To assess the usefulness of hyperpolarized helium (3He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. METHODS AND MATERIALS Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 x 8 Gy) using 4-MV photons. Conventional proton (1H) and hyperpolarized (3He) MRI wer...

متن کامل

Pulmonary kinematics from tagged hyperpolarized helium-3 MRI.

PURPOSE To propose and test the feasibility of a novel method for quantifying 3D regional pulmonary kinematics from hyperpolarized helium-3 tagged MRI in human subjects using a tailored image processing pipeline and a recently developed nonrigid registration framework. MATERIALS AND METHODS Following image acquisition, inspiratory and expiratory tagged (3)He magnetic resonance (MR) images wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002