Supraregional interlaboratory quality-control survey for an immunoradiometric renin assay.
نویسندگان
چکیده
specificities of 0.825 (confidence interval, 0.677– 0.916) and 0.965 (0.851– 0.995), respectively. We found that when RCVs from creatinine and urate combined were used to predict crises, the FP probability was reduced and there was a considerable increase in diagnostic specificity. The methodology used in this work pointed out the need to improve laboratory reports (13) as follows: • Include the RCV calculations for the combination of significant analytes for the pathology studied in the laboratory data processing system • Mark the test results showing a significant RCV with respect to the previous result • Include in the report a plot showing evolution of the analytes with a critical role in detecting changes in the pathology monitored A limitation of our RCV model to detect changes in the evolution of kidney graft recipients during monitoring is that it can only be applied to patients who have experienced a certain period of favorable clinical evolution. Regarding the usefulness of the model, we mention a few points. First, although the model can benefit only patients who have achieved an interval of clinical stability, these are precisely the ones in whom surveillance may be more relaxed (the patient has recovered from the operation and feels better; analyses are less frequent), and a specific, objective biochemical marker could be of greatest value. Second, the constituents providing an early indicator of rejection are among those analyzed in the standard protocol and at exactly the same frequency. Thus, no additional cost, effort, or discomfort to the patient is implied by the use of this approach (14). References 1. Harris EK. Some theory of reference values. Comparison of some statistical models of intraindividual variation in blood constituents. On the calculation of a " reference change " for comparing two consecutive measurements. Interpretation of serial measurements of international normalized ratio for prothrombin times in monitoring oral anticoagulant therapy. establishing biological variation in non-healthy situations: renal posttrans-plantation data. change value using specific enquiry in renal post-transplantation. Bioquimia 2000;25:85. 11. Henderson AR. Assessing test accuracy and its clinical consequences: a primer for receiver operating characteristic curve analysis. For the last 20 years, the most widely used method for assessment of the renin-angiotensin system has been the plasma renin activity assay (1). Although the assay gives useful information on the enzymatic function of the renin molecule, the intrinsic characteristics of this method limit its analytical accuracy (2). Immunoradiometric assays for renin, …
منابع مشابه
Two-site direct immunoassay specific for active renin.
A sensitive immunoradiometric assay, without an enzymatic step and specific for active human renin, was developed with use of two monoclonal antibodies (MAbs). In this assay system, the first MAb was coupled to magnetic beads (Magnogel); the second one, directed against the active form of the enzyme, was radiolabeled with 125I. The specificity of this assay was demonstrated in experiments measu...
متن کاملA new chemiluminescence immunoassay for triiodothyronine and thyroxine: evaluation using quality control sera assayed in an interlaboratory survey.
A recently developed chemiluminescence immunoassay system (LIA-mat) for triiodothyronine and thyroxine, set up by Byk-Sangtec Diagnostica (Dietzenbach, Germany), has been evaluated and compared with radioimmunoassays and with a chemiluminescence enhanced enzyme immunoassay (Amerlite), using control materials circulated in a national interlaboratory quality control, as well as patient sera. The ...
متن کاملImproved immunoradiometric assay for plasma renin.
BACKGROUND Our renin IRMA overestimated renin in plasmas with high prorenin-to-renin ratios. We suspected that the overestimation of renin was caused less by cross-reactivity of the renin-specific antibody with prorenin than by a conformational change of prorenin into an enzymatically active form during the assay. METHODS Because the inactive form of prorenin converts slowly into an active fo...
متن کاملPathophysiological significance of plasma total renin and prorenin in patients with diabetes mellitus.
To seek the pathophysiologic significance of measuring the concentration of total renin instead of prorenin, we determined the plasma total renin concentration by immunoradiometric assay and correlated the results with various clinical features and laboratory parameters of diabetic complication in 108 patients with diabetes mellitus. The plasma prorenin concentration was estimated as the differ...
متن کاملValidation of a new automated renin assay.
BACKGROUND Measurement of plasma renin is important for the treatment of patients with congenital adrenal hyperplasia (CAH) and in the evaluation of patients with suspected hyperaldosteronism. Immunologic assays for plasma renin offer easier implementation and standardization than enzyme-kinetic assays for plasma renin activity, but their sensitivity and specificity have been questioned. We stu...
متن کاملذخیره در منابع من