Assessing accuracy of a continuous screening test in the presence of verification bias

نویسندگان

  • Todd A. Alonzo
  • Margaret Sullivan Pepe
  • M. S. Pepe
چکیده

In studies to assess the accuracy of a screening test, often definitive disease assessment is too invasive or expensive to be ascertained on all the study subjects. Although it may be more ethical or cost effective to ascertain the true disease status with a higher rate in study subjects where the screening test or additional information is suggestive of disease, estimates of accuracy can be biased in a study with such a design.This bias is known as verification bias. Verification bias correction methods that accommodate screening tests with binary or ordinal responses have been developed; however, no verification bias correction methods exist for tests with continuous results. We propose and compare imputation and reweighting bias-corrected estimators of true and false positive rates, receiver operating characteristic curves and area under the receiver operating characteristic curve for continuous tests. Distribution theory and simulation studies are used to compare the proposed estimators with respect to bias, relative efficiency and robustness to model misspecification. The bias correction estimators proposed are applied to data from a study of screening tests for neonatal hearing loss.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification Bias—impact and Methods for Correction When Assessing Accuracy of Diagnostic Tests

• Sometimes it is not feasible to obtain disease status verification for all study subjects. Analysis of only those with disease ascertainment can result in biased estimates of the accuracy (sensitivity, specificity, ROC curve) of a diagnostic test, screening test, or biomarker if the estimation method does not properly account for the missing disease ascertainment. This paper discusses the imp...

متن کامل

Bias in trials comparing paired continuous tests can cause researchers to choose the wrong screening modality

BACKGROUND To compare the diagnostic accuracy of two continuous screening tests, a common approach is to test the difference between the areas under the receiver operating characteristic (ROC) curves. After study participants are screened with both screening tests, the disease status is determined as accurately as possible, either by an invasive, sensitive and specific secondary test, or by a l...

متن کامل

Reducing decision errors in the paired comparison of the diagnostic accuracy of screening tests with Gaussian outcomes

BACKGROUND Scientists often use a paired comparison of the areas under the receiver operating characteristic curves to decide which continuous cancer screening test has the best diagnostic accuracy. In the paired design, all participants are screened with both tests. Participants with suspicious results or signs and symptoms of disease receive the reference standard test. The remaining particip...

متن کامل

Estimates of sensitivity and specificity can be biased when reporting the results of the second test in a screening trial conducted in series

BACKGROUND Cancer screening reduces cancer mortality when early detection allows successful treatment of otherwise fatal disease. There are a variety of trial designs used to find the best screening test. In a series screening trial design, the decision to conduct the second test is based on the results of the first test. Thus, the estimates of diagnostic accuracy for the second test are condit...

متن کامل

Verification bias-corrected estimators of the relative true and false positive rates of two binary screening tests.

The relative accuracy of two binary screening tests can be quantified by estimating the relative true positive rate (rTPR) and relative false positive rate (rFPR) between the two tests. Ideally all study subjects are administered both screening tests as well as a gold standard to determine disease status. In practice, however, often the gold standard is so invasive or costly that only a percent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004