Can Tasers® directly cause ventricular fibrillation?

نویسندگان

  • J G Webster
  • J A Will
  • H Sun
  • J-Y Wu
  • A P O'Rourke
  • S M Huebner
  • P S Rahko
چکیده

Tasers are battery powered electrical devices used by law enforcement personnel to temporarily incapacitate a suspect. This study is a portion of a larger study to determine the probability of a Taser (X26 and M26) causing ventricular fibrillation (VF) in humans. We determined the distance between a Taser dart and the ventricle (dart-to-heart distance) necessary to trigger VF in an in-vivo porcine model, using 10 anesthetized pigs. All experiments were approved by the appropriate IUCUC and adhere to all applicable laws and standards of the NIH and USDA as well as the policies of the APS. To more accurately represent the dart-to-heart distances found in a human, we reflected the skin, subcutaneous fat and muscle over the sternum and placed a thoracic dart into the third intercostal space over the right ventricle. Current flowed to a second dart 15 to 54 cm away on the abdomen. We determined that the distance between the darts makes no significant difference in the current. We directly measured the dart-toheart distance and confirmed it post mortem. The dart-toheart distance that causes VF is 17 mm ± 6.48 (SD) for the first VF event and 13.7 mm ± 6.79 (SD) for the average of the successive VF events. We will combine these data with echocardiographic human anatomic data, police-provided dart landing distribution data, and a finite element method (FEM) model of current density in the human torso to yield a probability of a Taser causing VF in a human. . Keywords— electromuscular incapacitating device, Taser, ventricular fibrillation, echocardiography

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating the probability that the Taser directly causes human ventricular fibrillation.

This paper describes the first methodology and results for estimating the order of probability for Tasers directly causing human ventricular fibrillation (VF). The probability of an X26 Taser causing human VF was estimated using: (1) current density near the human heart estimated by using 3D finite-element (FE) models; (2) prior data of the maximum dart-to-heart distances that caused VF in pigs...

متن کامل

Modulation of extracellular atrioventricular node field potential pattern and ventricular rhythm by morphine in experimental atrial fibrillation in isolated rabbit heart

Introduction: Endorphins are produced by cardiomyocytes, and exert different effects on the heart. The aim of the present study is to assess morphine effects on extracellular atrioventricular (AV) node field potential pattern and ventricular rhythm of isolated rabbit heart during experimental atrial fibrillation (AF). Methods: Effects of different concentrations of morphine (10, 20, 50 and 1...

متن کامل

Mechanically induced sudden death in chest wall impact (commotio cordis).

Sudden death due to nonpenetrating chest wall impact in the absence of injury to the ribs, sternum and heart is known as commotio cordis. Although once thought rare, an increasing number of these events have been reported. Indeed, a significant percentage of deaths on the athletic field are due to chest wall impact. Commotio cordis is most frequently observed in young individuals (age 4-18 year...

متن کامل

Factors determining vulnerability to ventricular fibrillation induced by 60-CPS alternating current.

Very weak, 60-cps alternating current applied directly to the heart can cause ventricular fibrillation; greater current strength is required to induce ventricular fibrillation with a single shock delivered during the vulnerable period of the cardiac cycle. The present experiments were designed to examine the basis of this difference. The studies were performed in anesthetized open-chest dogs. T...

متن کامل

New manifestations of electrophysiological remodeling of heart during experimental model of atrial fibrillation in cirrhotic rat isolated heart

Introduction: The present study is aimed to evaluate electrophysiological remodeling of atrioventricular (AV) node and ventricular conduction during experimental atrial fibrillation (AF) model in isolated heart of cirrhotic rats. Methods: Cirrhosis-induced electrophysiological remodeling was evaluated in 24 isolated retrogradely perfused rat hearts in 2 groups (control and cirrhotic). Cirrho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006