Clinical validation of vessel-based registration for correction of brain-shift
نویسندگان
چکیده
The displacement and deformation of brain tissue is a major source of error in image-guided neurosurgery systems. We have designed and implemented a method to detect and correct brain shift using pre-operative MR images and intraoperative Doppler ultrasound data and present its validation with both real and simulated data. The algorithm uses segmented vessels from both modalities, and estimates the deformation using a modified version of the iterative closest point (ICP) algorithm. We use the least trimmed squares (LTS) to reduce the number of outliers in the point matching procedure. These points are used to drive a thin-plate spline transform to achieve non-linear registration. Validation was completed in two parts. First, the technique was tested and validated using realistic simulations where the results were compared to the known deformation. The registration technique recovered 75% of the deformation in the region of interest accounting for deformations as large as 20 mm. Second, we performed a PVA-cryogel phantom study where both MR and ultrasound images of the phantom were obtained for three different deformations. The registration results based on MR data were used as a gold standard to evaluate the performance of the ultrasound based registration. On average, deformations of 7.5 mm magnitude were corrected to within 1.6 mm for the ultrasound based registration and 1.07 mm for the MR based registration.
منابع مشابه
Compensation of brain shift during surgery using non-rigid registration of MR and ultrasound images
Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملSurface reconstruction of detect contours for medical image registration purpose
Although, most of the abnormal structures of human brain do not alter the shape of outer envelope of brain (surface), some abnormalities can deform the surface extensively. However, this may be a major problem in a surface-based registration technique, since two nearly identical surfaces are required for surface fitting process. A type of verification known as the circularity check for th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical image analysis
دوره 11 6 شماره
صفحات -
تاریخ انتشار 2007